R.F. PENTODE
G.6.C!
R.F. PENTODE
A3064
-
VALVES
ISSUE 1
An r. f. pentode suitable for use in applications where long life and c...
Description
G.6.C!
R.F. PENTODE
A3064
-
VALVES
ISSUE 1
An r. f. pentode suitable for use in applications where long life and close control of characteristics are required.
-
The A3064 will replace the CV138, CV4014 and Z77 in most applications. BASE CONNECTIONS AND VALVE DIMENSIONS
Ih ha
Base: Small-button miniature (B7G)
Bulb:
Tubular
k
g3,S
Max. overall length :
54.5mm
Max. seated length:
47.5mm
gl
gz Max. diameter:
19mm
Viewed from underside of base.
6.3 V 0.3 A
MAXIMUM RATINGS (Absolute)
Va(o) Va
550 300
Pa
I Vg2(o) Vg2 Pg2
2.5 450 300
0.8
Rgl-k
0.5
Vh-k (heater positive)
100
-Vh-k (heater negative)
250
Tbulb
200
V V W V V W MQ V V °C
CAPACITANCES (Measured on a cold screened valve) Cgl-alliess a: 6.5-8. 7pF ca-alliess gl: Ca-gl: O.OlpF (max)
2.75-3. 75pF
THE M-O VALVE CO. LTD· BROOK GREEN WORKS· LONDON· W.6
-.------------------------------------------------------------------------------SEPTEMBER 1963
A3064
CHARACTERISTIC SPREAD
Measured at :
Va Vg2 Vg1 Rk
250 250
0 160
V V V
Q
*Ia Ig2
*gm -Ig
Ia (at -Vgl ~ 8V)
*f.1 *-Vg3 (at -Vgl ~ 3.5V,
Ia ~ 50f.1A)
Ih
Min. 8.7 1.8 6.8
60
70 275
Mean 9.85 2.6 7.62
75
95 300
Max. 11. 0
3.4 8.43 0.5 100 89
120 325
rnA rnA mA/V f.1A f.1A
V rnA
*These tests are performed on a sample basis only, and the figures given are of the average spread.
LIFE PERFORMANCE
The average life expectancy of the A3064 is at least 10,000 hours. In order to obtain maximum life, the valve must be operated within the rating...