Document
GBU601 THRU GBU607
SINGLE PHASE 6.0 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
6.0 Amperes
FEATURES
* Ideal for printed circuit board * Low forward voltage * Low leakage current * Polarity: marked on body * Mounting position: Any
GBU
.880(22.3) .860(21.8)
.232(5.9) .224(5.7)
.100(2.54) .085(2.16)
.154(3.9) .146(3.7)
AC
+
.083(2.1) .067(1.7)
.060(1.52) .045(1.14)
.050(1.27) .040(1.02)
.210(5.33) .190(4.83)
SPACING
.024(0.6) .016(0.4)
.139(3.5) .133(3.4)
.752(19.1) .720(18.3)
.720(18.29) .680(17.27)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current
GBU601 GBU602 GBU603 GBU604 GBU605 GBU606 GBU607 UNITS
50 100 200 400 600 800 1000 V 35 70 140 280 420 560 700 V 50 100 200 400 600 800 1000 V
.375"(9.5mm) Lead Length at Tc=100 C Peak Forward Surge Current, 8.3 ms single half sine-wave
6.0 A
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 3.0A D.C.
Maximum DC Reverse Current
Ta=25 C
175 1.0 5.0
A V A
at Rated DC Blocking Voltage Operating Temperature Range, TJ Storage Temperature Range, TSTG
Ta=100 C
500 -65 +150 -65 +150
A
C C
AVERAGE FORWARD CURRENT,(A)
RATING AND CHARACTERISTIC CURVES (GBU601 THRU GBU607)
FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE
9
8 7 6 5
4
Single Phase
3
Half Wave 60Hz
2 Resistive Or Inductive Load 1 0
0 20 40 60 80 100 120 140 160
CASE TEMPERATURE,( C)
PEAK FORWARD SURGE CURRENT,(A)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
250
200 175 150
100
50
Tj=25 C
8.3ms Single Half Sine Wave JEDEC method
0
1
5 10
50 100
NUMBER OF CYCLES AT 60Hz
INSTANTANEOUS FORWARD CURRENT,(A)
FIG.3-TYPICAL FORWARD CHARACTERISTICS
50
10 3.0 1.0
0.1
Tj=25 C
Pulse Width 300us 1% Duty Cycle
.01 0
.2 .4 .6 .8 1.0 1.2 1.4
FORWARD VOLTAGE,(V)
REVERSE LEAKAGE CURRENT, ( A)
FIG.4-TYPICAL REVERSE CHARACTERISTICS
50
10 3.0 Tj=100 C 1.0
0.1
Tj=25 C
.01 0 20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
.