FEATURES
Small DIP-16 Plastic Package 23.8 x 13.7 x 8.0 mm (0.94 x 0.54 x 0.31 inches) Wide 2:1 Input Range Fully regulated Output Operating Temp. Range –40°C to +80°C Short Circuit Protection I/O-isolation 1500 VDC Input Filter meets EN55022,class A and FCC, level A Cost optimized Design CSA/UL/IEC/EN 60950-1 Safety Approval 3 Year Product Warranty
MDW1000 SERIES
DC/DC CONVERTER 2W, DIP-Package
PRODUCT OVERVIEW
The MINMAX MDW1 series is a range of isolated 2W DC/DC converter modules featuring fully regulated output voltages and wide 2:1 input voltage ranges. The products come in a compact DIP-16 package with a low height of just 8.0 mm (0.31 inch). An excellent efficiency allows an operating temperature range of –40°C to +80°C. These DC/DC converters offer an economical solution for many cost critical applications in battery-powered equipment and instrumentation.
Model Selection Guide
Model Number
Input Voltage
(Range)
MDW1011 MDW1012 MDW1013 MDW1014 MDW1015 MDW1016 MDW1017 MDW1021 MDW1022 MDW1023 MDW1024 MDW1025 MDW1026 MDW1027 MDW1031 MDW1032 MDW1033 MDW1034 MDW1035 MDW1036 MDW1037 MDW1041 MDW1042 MDW1043 MDW1044 MDW1045 MDW1046 MDW1047
VDC 5
(4.5 ~ 9)
12 (9 ~ 18)
24 (18 ~ 36)
48 (36 ~ 75)
Output Voltage
VDC 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15
Output Current
Max. Min. mA mA 500 125 400 100 167 42 134 33 ±200 ±50 ±83 ±21 ±67 ±17 500 125 400 100 167 42 134 33 ±200 ±50 ±83 ±21 ±67 ±17 500 125 400 100 167 42 134 33 ±200 ±50 ±83 ±21 ±67 ±17 500 125 400 100 167 42 134 33 ±200 ±50 ±83 ±21 ±67 ±17
Input Current
@Max. Load
mA(typ.) 471 548 534 582 667 615 598 184 217 209 220 242 224 226 96 109 109 108 119 112 110 49 57 53 55 62 57 57
@No Load mA(typ.)
40
20
10
8
Reflected Max. capacitive
Ripple
Load
Current
mA(typ.)
F
2200
1000
170
100 110
470#
100#
47#
2200
1000
170
25 110
470#
100#
47#
2200
1000
170
15 110
470#
100#
47#
2200
1000
170
10 110
470#
100#
47#
# For each output
Efficiency
(typ.)
@Max. Load
% 70 73 75 73 64 69 71 73 77 80 80 73 78 78 72 77 80 81 74 78 80 71 73 79 79 71 77 77
E-mail:
[email protected] Tel:886-6-2923150
2013/05/16 REV:7 Page 1 of 4
MDW1000 SERIES
DC/DC CONVERTER 2W, DIP-Package
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
Under Voltage Shutdown
Reverse Polarity Input Current Short Circuit Input Power Internal Power Dissipation Conducted EMI
Model 5V Input Models 12V Input Models 24V Input Models 48V Input Models 5V Input Models 12V Input Models 24V Input Models 48V Input Models 5V Input Models 12V Input Models 24V Input Models 48V Input Models
All Models
Min. Typ. Max. Unit
-0.7 ---
11
-0.7 ---
25
-0.7 ---
50
-0.7 --- 100
3.5 4 4.5
4.5 7
9 VDC
8 12 18
16 24 36
--- 3.5
4
--- 6.5 8.5
--- 11 17
--- 22 34
--- --- 1 A
--- --- 1500 mW
--- --- 1800 mW
Compliance to EN 55022,class A and FCC part 15,class A
Output Specifications
Parameter Output Voltage Setting Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Transient Recovery Time Transient Response Deviation Temperature Coefficient Short Circuit Protection
Conditions At 50% Load and Nominal Vin Dual Output, Balanced Loads
Vin=Min. to Max. Io=25% to 100%
25% Load Step Change
Min. Typ. --- ----- ±1.0 --- ±0.3 --- ±0.5 --- 30 --- 100 --- ±3 --- ±0.01
Continuous
Max. ±2.0 ±2.0 ±0.5 ±0.75 50 300 ±5 ±0.02
Unit %Vom.
% % % mV P-P sec % %/
General Specifications
Parameter I/O Isolation Voltage (rated) I/O Isolation Resistance I/O Isolation Capacitance Switching Frequency MTBF (calculated) Safety Approvals
Conditions
Min. Typ. Max.
60 Seconds
1500 ---
---
500 VDC
1000 ---
---
100KHz, 1V
--- 250 420
--- 300 ---
MIL-HDBK-217F@25 , Ground Benign
1,000,000
---
---
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Unit VDC M pF KHz Hours
Input Fuse
5V Input Models 1000mA Slow-Blow Type
12V Input Models 500mA Slow-Blow Type
24V Input Models 250mA Slow-Blow Type
48V Input Models 120mA Slow-Blow Type
Environmental Specifications
Parameter Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature Storage Temperature Range Humidity (non condensing) Cooling Lead Temperature (1.5mm from case for 10Sec.)
Conditions Natural Convection
Min. -40 ---55 --Free-Air convection ---
Max. +80 +90 +105 95
260
Unit % rel. H
E-mail:
[email protected] Tel:886-6-2923150
2013/05/16 REV:7 Page 2 of 4
Power Derating Curve
MDW1000 SERIES
DC/DC CONVERTER 2W, DIP-Package
Output Power (%)
Notes
1 Specifications typical at Ta=+25 , resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3 Ripple & Noise measurement bandwidth is 0-20 MHz. 4 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions wi.