MAGNETIC SENSOR
MP1005-1007 Series
Applications: Limit Switch Specifications
Solid state magnetic proximity sensor in...
MAGNETIC SENSOR
MP1005-1007 Series
Applications: Limit Switch Specifications
Solid state magnetic proximity sensor in adjustable threaded housing.
Features
Excellent output stability over Open Collector (
NPN) output can
operating temperature
be used with bipolar or cmos
range.
logic circuits with suitable pull up
Regulated power supply not
resistor.
needed.
- Output switches low (off) when
Reverse battery protection to -
the magnetic field at the sensor
24VDC. Wire: 20awg, tin plated,
Radox 150A, Polyolefin insulation Anodized aluminum housing South pole activated, works
exceeds the operate point threshold - Output switches high (on) when the magnetic field is reduced to below the release point threshold
with AS101001 magnet.
Home security
Door position
Note: These sensors require the use of an external pull-up resistor , the value of which is dependent upon the supply voltage. Pull-up resistor should be connected between output (Black) and Vcc (Brown).
Dimensions inches (mm)
Open Collector Sinking Block Diagram
Specifications subject to change without notice.
Recommended pull-up resistor values:
Volts DC: 5
9 12 15
Ohms: 1K 1.8K 2.4K 3K
24 3K
Last Update 072512
...