STAND-ALONE PROXIMITY
Edition 02/2000
DG502
Y2K
STAND-ALONE PROXIMITY SYSTEM 500 PROXIMITY BADGES 2 DOORS
Wiring diagram
WIRING DIAGRAM A...
Description
Edition 02/2000
DG502
Y2K
STAND-ALONE PROXIMITY SYSTEM 500 PROXIMITY BADGES 2 DOORS
Wiring diagram
WIRING DIAGRAM AND INSTRUCTIONS
PCB front view
1 4
2 5 8 0
3 6 9
Warning
Do not use a switching power supply because of the interference radiation that may disturb the reading of the badges
12 3
7 …
ST1
#
RL1
RL2
R C T R C T S S B M E 1 2 3 4 5 6 12 V 12 V Strike
M A G N E T
PB1 PB2
V1
V2
230V~
Input voltage 12V ~ or = B E M R C T V1 V2 ST1 S, S RL1 RL2 Push button 1 Push button 2 Common PB1 PB2 N/C contact Common N/O contact Varistor RL1 Varistor RL2 Reset jumper Trigger output Door 1 relay output Door 2 relay output
Auxiliary reader (terminal connections) See wiring diagram of auxiliary readers
12 V 1 2 3 4 5 Input voltage Input voltage Data Buzzer Green LED Common Red LED
12 V 1 4 5 3 2
This device comes with a varistor. The varistor must be connected to the strike terminal (electromagnet…) operated by the device. If this product works with many strikes, each of them should have a varistor. The varistor controls the overload produced by the strike coil – self-effect. If you are using a « Shear Lock » electromagnetic lock, it is recommended to use a separate power supply than the one connected to the DG502 !
Edition 17/02/00
Technical features
Input voltage Output Anti-triggering contact Badge entry Master code Inputs Keyboard Distance between the auxiliary reader and the main reader 12V ~ or = 2 relays, N/O & N/C contact 3 amp @ 125V 500 milli amp 50V...