Description LED Lighting Surge Protection
Datasheet LSP05240LLP DatasheetLSP05240LLP Datasheet (PDF)

LSP05 Module Series Surge Protection Module LED Lighting Surge Protection Module > LSP05 RoHS Description The Littelfuse LSP05 thermally protected Surge Protective Device is a self-protected device which is specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It is constructed with Littelfuse thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic fai.

  LSP05240LLP   LSP05240LLP


Document
LSP05 Module Series Surge Protection Module LED Lighting Surge Protection Module > LSP05 RoHS Description The Littelfuse LSP05 thermally protected Surge Protective Device is a self-protected device which is specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It is constructed with Littelfuse thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under the extreme circumstances of varistor end-of-life or sustaining over voltage conditions. The LSP05 facilitates customer’s product compliance to IEEE C62.41.2 Location Category C Low and US Dept of Energy MSSLC Model Spec. Agency Approvals Agency Standard UL1449 Agency File Number E320116 Applications • Outdoor and Commercial LED Lighting • Roadway lighting • Traffic lighting • Digital signage • Wash wall lighting • Parking garage/lot lighting • Flood lighting • Tunnel lighting • Street lighting Additional Information Datasheet Resources Samples Features • Maximum Discharge connected modules Current, 10kA, 8/20us • UL 1449 Type 4 • Meets ANSI C82.77- Component Assembly 5-2015: Location Recognition (Type 4CA) Category CM, 10kV/5kA, 1.2/50µS-8/20µS Combination Wave. • IEC61643-11 Class II/ EN61643-11 Type 2 Compliant1 • Meets IEEE C62.41.2: • Compact form factor Location Category CLow, (48x48x30mm) with 6kV/3kA, 1.2/50µS-8/20µS mounting tabs Combination Wave. • 240Vac and 277Vac • Meets US Dept. voltage ratings are of Energy MSSLC available for Class I Model Spec. and Class II installation • Parallel connected based on IEC luminaire SPD device protection classes • Thermally protected • CE - Meets the Varistor technology requirements of Low • IP66 Water-proof and Dust-proof Voltage and RoHS European Directives. • Indication wire lead options for Parallel Notes: 1. Self-declared compliance. Absolute Maximum Ratings • For ratings of individual members of a series, see Device Ratings and Specifications chart LSP05 Series Units Continous Steady State Applied Voltage: Transient Max AC Voltage Range (VM(AC)RMS) Maximum Discharge Current 8/20μs Waveform (Imax) Nominal Discharge Current 8/20µs Waveform (In) Operating Ambient Temperature Range (TA) Storage Temperature Range (TSTG) Isolation Voltage Capability (When the thermal disconnect opens) Insulation Resistance 150 to 510 10,000 5,000 -45 to +85 -45 to +125 600 >1,000 V A A °C °C V MΩ CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. © 2019 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 11/04/19 Surge Protection Module LED Lighting Surge Protection Module > LSP05 LSP05 Series Device Ratings & Specifications Part Number7 LSP05120* Operating Voltage (VAC) 120 LSP05240* 240 LSP05277* 277 LSP05347* 347 LSP05480* LSP05240LL* LSP05480LL* 480 L-L:240 L-N/G:120 L-L:480 L-N/G:277 MCOV/Uc (VAC)5 150 275 320 420 510 L-L:275 L-N/G:150 L-L:510 L-N/G:320 Maximum Discharge Current (Imax)(A)2 10,000 10,000 10,000 10,000 10,000 10,000 10,000 Nominal Discharge Current (In)(A)1 5,000 5,000 5,000 5,000 5,000 5,000 5,000 MLV (V)3 L-N:680 L-G:680 N-G:630 L-N:1070 L-G:1050 N-G:1020 L-N:1260 L-G:1280 N-G:1220 L-N:1590 L-G:1590 N-G:1570 L-N:1780 L-G:1800 N-G:1740 L-L:1070 L-N/G:680 L-L:1780 L-N/G:1280 Up (V)4 800 1200 1400 1700 1900 L-L:1200 L-N/G:800 L-L:1900 L-N/G:1400 Safety Compliance IEC/EN 61643-116 UL1449 X XX XX X X X X X X Notes: 1. Nominal Discharge Current (In)(A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20us current waveform. 2. Maximum Discharge Current (Imax)(A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20us current waveform. 3. MLV – UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20us nominal discharge current (In); an average voltage value of 15 impulses 4. Up – IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20us nominal discharge current (In); a rounding voltage value of maximum measurement. 5. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. 6. Part Numbers LSP05xxxPM Only. 7. * = - P or PM 8. Repetitive Surge Withstanding: 15 strikes at 5,000A (8/20us) with steady MLV/Up. Figure 1. Repetitive Surge Capability for LSP05 SURGE.


LSP05480P LSP05240LLP LSP05480LLP


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)