Document
Model: GP‐LP060P Series
Features
Universal AC input 90‐‐305Vac. Class 2 Power Supply Unit. Constant Voltage dimming by PWM/1‐10v/Resistor Operation. Built in 2 stage ACTIVE PFC Function. Protections: OVP / OCP / SCP / OTP. Fully Insulated Case with IP67 Level. Cooling by free air convection. Optional Dimming Type : GP‐LP060‐12□□ □: A for Dimming type. □: V for Constant Voltage / C for Constant current Dimming.
Approvals
Size
163 * 45 * 33 mm (L*W*H)
Specifications
Model No.
DC Voltage Range Rated Current Max.Power Ripple&Noise(Max.) Note.2 PWM Dimming Frequency Voltage/ Tolerance Efficiency at 230Vac Set up time (Max.) Voltage Range Frequency Range AC Current (Max.) Input Power Factor Inrush Current (Max.) Leakage Current Over Current Protections Short Circuit Over Voltage Over Temperature
GP‐LP060P‐12VA
12V 5A 60W 0.3Vp‐p 800‐1000 Hz ±2% 85%
GP‐LP060P‐24VA
24V 2.5A 60W 0.3Vp‐p
Output
1 sec. / 230V AC, 2 sec. / 115V AC, at full load. 90 ~ 305V AC or 127 ~ 430V DC 47 Hz ~ 63 Hz 1A at 115V AC / 0.5A at 230V AC >0.95 at 115 V AC / >0.9 at 230V AC with full load. 60A at 230 V AC <0.5mA / 240 V AC 200% rated current. Type: Shut down and Autorecovers after fault condition disappeared. Type: Shut down and Autorecovers after fault condition disappeared. 110%‐150% rated output voltage Type: Latch OFF Mode. Type: Latch OFF Mode.
Operation Temp. Operation Humidity Environment Storage Temp. Storage Humidity Vibration Safety Standards Withstand Voltage Isolation Resistance Safety & EMC EMI Conduction & Radiation Harmonic Current EMS Immunity MTBF Dimension Others (L x W x H) Packing (L x W x H)/Carton Weight ‐20°C ~50°C ambient operating at full load (Refer to output load derating curve) 20% ~ 90% RH non‐condensing. ‐40 ~ +80°C 10% ~ 90% RH 10~500 Hz, 2G 10 min./1 cycle, period for 60 min. each along X, Y, Z axes. EN61347‐1,EN61347‐2‐13 ,IP67/UL8750/UL60950 Approved. I/P ‐ O/P: 3.75K VAC I/P‐O/P:100M ohms / 500VDC at 25°C EN55015 EN61000‐3‐2 Class C,EN61000‐3‐3 EN61000‐4‐2,3,4,5,6,8,11 Light industry level, criteria A 200K hours min.MIL‐HDBK‐217F(25°C) 163 x 45 x 33mm 590 x 224 x 150mm 0.37kg
1. All specifications not specially mentioned are measured at 115Vac and 25°C ambient temperature. Note 2. Ripple & Noise are measured at 20MHz bandwidth with 0.1uf ceramic & 47uf electrolytic capacitors in parallel. 3. Voltage Tolerance: includes line regulation, load regulation and set‐up tolerance.
Derating Curve
Load 230V 100% 80% 115V 60% 40% HORIZONTAL 20% 0 -20 20 40 50 60 AMBIENT TEMPERATURE (℃ )
Block Diagram (Dimming function by optional)
Applications
Mechanical Specification
.