Logic
Specialty Safety Relays
MSR42 Multi-function
Specifications
Safety Ratings Standards Safety Classification EN 954...
Logic
Specialty Safety Relays
MSR42 Multi-function
Specifications
Safety Ratings Standards Safety Classification EN 954-1, IEC/EN 60204-1, IEC 61496-1 Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 61508, PLe per ISO 13849-1
PFHD: < See website Functional Safety Data 9 MTTFd: > See website Note: For up-to-date For use in SIL3 systems (according to IEC information, visit 61508) depending on the architecture and http://www.ab.com/Safety/ application characteristics Certifications Power Supply Input Power Entry Power Consumption Inputs Safety Inputs Input Resistance, Max. Reset Power On Delay Time Response Time Outputs Auxiliary Contacts Enclosure Type Rating/ Terminal Protection Operating Temperature [C (F)] Vibration Mounting Weight [g (lbs)] Conductor Size, Max. 2
PNP, configurable IP20/ IP20 0…55° (32…131°) 0.35 mm 10…55 Hz 35 mm DIN rail 130 (0.287) 1 x 2.5 mm2 (14 AWG) stranded Safety Contacts 2 N.C. or 2 OSSD, Micro 400 software selectable — Auto./manual or manual monitored Determined by configuration Determined by configuration 2
PNP, 400 mA each 24V DC 2.4 W (semi-conductor outputs unloaded) CE Marked for all applicable directives, cULus, and TÜV
The MSR42 has four software configurable inputs. These configurable safety inputs allow the connection of a multitude of safety devices such as safety light curtains, safety laser scanners, e-stops, safety switches, etc. This 22.5 mm DIN mount multi-function safety module has both hard wired and software configurable ...