Description
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
No. OB327
SERVICE MANUAL
Wireless type Models
MSZ-A09YV MSZ-A12YV -
E1
(WH) (WH)
E1
CONTENTS
1. PART NAMES AND FUNCTIONS······················2 2. SPECIFICATION·················································4 3. NOISE CRITERIA CURVES ·······························5 4. OUTLINES AND DIMENSIONS ·························6 5. WIRING DIAGRAM ············································7 6. REFRIGERANT SYSTEM DIAGRAM ················7 7. SERVICE FUNCTIONS ······································8 8. TROUBLESHOOTING······································10 9. DISASSEMBLY INSTRUCTIONS ····················19 10. PARTS LIST······················································21 11. OPTIONAL PARTS ···········································23
Indication of model name MSZ-A09YV - E1 MSZ-A12YV - E1
NOTE: This service manual describes technical data of the indoor units. Refer to the service manual OB328 when MSZ-A09YV- E1 or MSZ-A12YV- E1 is connected with MUZ-A09YV- E1 , MUZ-A12YV- E1 , MUZ-A09YVH- E1 or MUZ-A12YVH- E1 . Refer to the service manual OB319 when MSZ-A09YV- E1 or MSZ-A12YV- E1 is connected with MXZ-A18WV- E1 , MXZ-A26WV- E1 or MXZ-A32WV- E1 as multi system units.
http://www.Datasheet4U.com
1
PART NAMES AND FUNCTIONS
INDOOR UNIT MSZ-A09YV - E1 MSZ-A12YV - E1
Air cleaning filter (white bellows type) Heat exchanger Panel Catechin air filter (With deodorizer) to Breaker Power supply cord Remote control receiving section Front p...