Make & Break Load Switching
GH2: No Load Switching - GH4: Make & Break Load Switching - GH6: Make Only Load Switching RoHS Compliant, date code 0601...
Description
GH2: No Load Switching - GH4: Make & Break Load Switching - GH6: Make Only Load Switching RoHS Compliant, date code 0601 and later
GH 8kV SERIES Easy to mount threaded base with jam nut User interchangeable coils provide for driver versatility Meets or exceeds standards set in MIL-R-83725 GH2 - No Load Switching Low, stable contact resistance minimizes voltage drop in sensitive circuits High carry current, 25Adc continuous, in a small package GH4 - Make & Break Load Switching Durable tungsten contacts for hot load switching Vacuum dielectric for effective arc quenching when opening under load GH6 - Make Only Load Switching Excellent for capacitive discharge and safety dump switch applications Can be modified to accommodate customer specified cables and connectors Consult factory for load switching apps.
Contact & Relay Ratings
Contact Form Contact Arrangement Voltage, Test Max., Contacts & to Base (15 µA Leakage Max., dc or 60Hz) Voltage, Operating Max., Contacts & to Base (15 µA Leakage Max.)
dc or 60 Hz 2.5 MHz 16 MHz 32 MHz
Units
GH2
C SPDT
GH4
C SPDT 10
GH6
C SPDT 10
Nominal, Volts dc
Pick-up, Volts dc, Max. Drop-Out, Volts dc Coil Resistance (Ohms ±10%)
12
8 80
26.5 115
16 335 80 6000
.5 - 5 1 - 10 5 - 50
kV Peak
10
Ratings listed are for 25°C, sea level conditions kV Peak kV Peak kV Peak kV Peak Amps Amps Amps Amps V pF pF ohms ms ms cycles g (oz) G's G's °C 8 25 500 0.01 6 6 2 million 39 (1.4) 10 50 -55 to +125 8 15 500 0.02 6 6 2 million 39 (1.4) 10 50 -55...