Platinum temperature sensor
Platinum temperature sensor in thin-film technology
M 416
M-series platinum temperature sensors are characterized by l...
Description
Platinum temperature sensor in thin-film technology
M 416
M-series platinum temperature sensors are characterized by long-term stability, excellent precision over a wide temperature range and compatibility. They are used particularly for applications with high consumption volumes, typically in the automotive, white goods, HVAC and energy generation industries as well as in medical and industrial appliances and machinery.
Nominal Resistance R0
100 Ohm at 0°C
Tolerance DIN EN 60751 1996-07 Class 1/3 B Class A Class B
Tolerance DIN EN 60751 2009-05 F 0.1 F 0.15 F 0.3
Order Number Plastic Bag
Order Number Blister reel
32 208 217 32 208 216 32 208 213
32 208 701 32 208 279 32 208 278
The measuring point for the nominal resistance is defined at 8mm from the end of the sensor body.
Specification Temperature range
DIN EN 60751 -70°C to +500°C (continuous operation) (temporary use to 550°C possible) Tolerance Class B: -70°C to +500°C Tolerance Class A: -50°C to +300°C Tolerance Class 1/3 B: 0°C to +150°C TC = 3850 ppm/K
Temperature coefficient Leads
Pt clad Ni- wire
Recommend connection technology: Welding, Crimping and Brazing
Lead lengths (L)
Long-term stability Vibration resistance
10mm ±1mm
Max. R0 drift 0.04% after 1000h at 500°C At least 40g acceleration at 10 to 2000 Hz, depends on installation At least 100g acceleration with 8ms half sine wave, depends on installation Use unprotected only in dry environments > 100 M at 20°C; > 2 M at 500°C 0.4 K/mW at 0°C Wa...
Similar Datasheet