DatasheetsPDF.com

RAC04-0512DA Dataheets PDF



Part Number RAC04-0512DA
Manufacturers Recom
Logo Recom
Description AC/DC-Converter
Datasheet RAC04-0512DA DatasheetRAC04-0512DA Datasheet (PDF)

Features Regulated Converters ● ● ● ● ● ● ● ● Ultracompact AC-DC Power Supply 4 Watt PCB Mount Package Universal Input Voltage Range including 277VAC 3kVAC Isolation (Class II) Very Low No Load Input Current Dual output version for standby relay circuits Short Circuit Protected EN/UL Certified, CE Marked. The RAC04 series is an ultra-compact universal input AC/DC power module for PCB mounting. It features ultralow no-load power consumption, short circuit, overload and output overvoltage protec.

  RAC04-0512DA   RAC04-0512DA



Document
Features Regulated Converters ● ● ● ● ● ● ● ● Ultracompact AC-DC Power Supply 4 Watt PCB Mount Package Universal Input Voltage Range including 277VAC 3kVAC Isolation (Class II) Very Low No Load Input Current Dual output version for standby relay circuits Short Circuit Protected EN/UL Certified, CE Marked. The RAC04 series is an ultra-compact universal input AC/DC power module for PCB mounting. It features ultralow no-load power consumption, short circuit, overload and output overvoltage protection as well as a built-in EMC Class B filter . A high input voltage version (suffix /277) is also available for input voltages of up to 305VAC or 430VDC. POWERLINE AC/DC-Converter with 3 year Warranty Description Selection Guide Part Number RAC04-3.3SA RAC04-05SA RAC04-09SA RAC04-12SA RAC04-15SA RAC04-24SA Input Range (VAC)* (Std) (/277) 90-264 90-305 90-264 90-264 90-264 90-264 90-264 90-264 90-305 90-305 90-305 90-305 90-305 90-305 Output Voltage (VDC) 3.3 5 9 Output Current (mA) 1200 800 444 333 267 167 Efficiency (%) 68 72 75 76 76 77 75 Max Capacitive Load 14000µF 8000µF 2400µF 1000µF 700µF 220µF 4 Watt Single/Dual Output RAC04-0512DA NOT RECOMMENDED FOR NEW DESIGNS 12 15 24 5/12 120/250 standard /277 versions 4700/330µF 2011/65/EU 6/6 RoHS * add suffix /277 for 90-305VAC input. High input voltage converters are identified by omitting pin 1. E196683 EN 55022/55024 Certified UL-60950-1 Certified Specifications (typical at 25°C and after warm up time unless otherwise specified ) Input Voltage Range Rated Power Input Frequency Range (for AC Input) Input Current (full load) No Load Power Consumption Inrush Current (<0.5ms) Leakage Current Output Voltage Accuracy (full load) 90-264VAC or 120-370VDC 90-305VAC or 120-430VDC 4 Watts max 47-440Hz 95/65mA max. 75/55mA max. 150/210/220mW typ. 15/25A max. 0.25mA max ±2% ±0.5% ±5%/±2% ±0.2% typ ±3%/±0.2% typ ±1% typ ( ±0.5% typ ±5%/±0.5% typ <250mVp-p max <200mVp-p max. 100mVp-p max 132kHz typ 15ms min. 0% 25% 3kVAC / 1minute ±0.02%/°C typ 100 MΩ max Hiccup, Automatic Restart Zener Clamping Diode -40°C to +70°C -40°C to +70°C -40°C to +85°C 95% RH max continued on next page REV: 1/2014 RAC04 115/230VAC /277 115/230/277VAC 115/230VAC RAC04-A Derating Graph (Ambient Temperature) 125 100 Output Power (%) single outputs 3.3V (/277 Version) Dual output version 5V/12V Line Voltage Regulation (low line, high line at full load) Dual output version 5V/12V Load Voltage Regulation 3.3V output 0% to 100% full load ) All others Dual output version 5V/12V Output Ripple and Noise 3.3V output (measured @ 20MHz of bandwith with 5V output 0.1µF & 47µF parallel capacitor) All others Operating Frequency Hold-up time single outputs Minimum Load 5V/12V RMS Isolation Voltage (input to output) Temperature Coefficient Isolation Resistance Short Circuit Protection Output Overvoltage Protection All others Operating Temperature Range (natural convection, with derating) Dual output version Storage Temperature Range Humidity .


RAC04-24SA RAC04-0512DA RAC04-3.3SC-277


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)