100W Single Output Switching Power Supply
1 0 0 W S i n g l e O u t put Switching Power Supply
RS100
Universal AC input Protections:Short circuit/Over load/Over ...
Description
1 0 0 W S i n g l e O u t put Switching Power Supply
RS100
Universal AC input Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on All using 105°C long life electrolytic capacitors High efficiency, long life and high reliability
series
Model Number
SINGLE OUTPUT RS100-3.3 RS100-5 RS100-12 RS100-15 RS100-24 RS100-48
Output Volts
Output Amps
Ripple & Noise
Min Load
DC Volt Adjust Load Reg Volt Tolerance
3.3 Volts(DC) 5 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 48 Volts(DC)
20 Amps 16 Amps 8.5 Amps 7.0 Amps 4.5 Amps 2.3 Amps
80mV pk-pk 80mV pk-pk 120mV pk-pk 120mV pk-pk 120mV pk-pk 200mV pk-pk
0~20Amps 0~16Amps 0~8.5Amps 0~7.0Amps 0~4.5Amps 0~2.3Amps
3.2~3.5Volt(DC) 4.75~5.5Volt(DC) 11.4~13.2Volt(DC 14.25~16.5Volt(DC) 22.8~26.4Volt(DC) 45.6~52.8Volt(DC)
±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458
Free Datasheet http://www.Datasheet4U.com
1 0 0 W S i n g l e O u t put Switching Power Supply
INPUT SPECIFICATIONS
Input Voltage Range Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current Min Load 90 ~ 264 VAC; 125~373 Volts(DC) 47-63 Hz 40Amps / 230VAC 2.5 Amps. @ 115VAC 1.5 Amps. @ 230VAC < 2mAmps /240VAC See Selection Chart
RS100
series
OUTPUT SPECIFICATIONS
Voltage and Current Line Regu...