Document
Snap-In Aluminum Electrolytic Capacitors
PEH536 Series, +105ºC
Overview
Applications
Typical applications for KEMET's PEH536 capacitor include switch mode power supplies (SMPS), drives, welding equipment, uninterruptible power supplies (UPS), and other power electronic applications where high current ratings and compact size are important.
KEMET's PEH536 is a long-life electrolytic capacitor designed to offer high ripple current capability and low mounting cost. Low ESR is the result of a very low resistive paper/electrolyte system. Low ESR, together with the TDC thermal concept, gives the PEH536 a high ripple current capability.
Benefits
• Snap-In • 6,000 hours at +105°C • PCB mounting • Low ESR and ESL • High ripple current
Part Number System
PEH536
Series Snap-In type Aluminum Electrolytic
J
Voltage (VDC) J = 35 M = 63 P = 100 R = 200 S = 250 U = 350 V = 400 Y = 450
AD
Size Code See Dimension Table
439
Capacitance Code (µF) The second two digits indicate the two most significant digits of the capacitance value. The first digit indicates the total number digits.
0
Version 0 = Standard
M
Capacitance Tolerance M = ±20%
2
Termination See Termination Table
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4025_PEH536 • 9/9/2013 1
Free Datasheet http://www.Datasheet4U.com
Snap-In Aluminum Electrolytic Capacitors – PEH536, +105ºC
Performance Characteristics
Item
Capacitance Range Rated Voltage Temperature Range Capacitance Tolerance Operational Lifetime Shelf Life Leakage Current 47 – 18,000 µF 35 – 450 VDC -40 to +105°C ±20% at 100 Hz / +20°C +105°C (hours) 6,000 4 years at +40°C 0 VDC I = 0.003 CV (µA) C = rated capacitance (µF), V = rated voltage (VDC). Voltage applied for 5 minutes at +20°C. Procedure Vibration Test Specifications 0.75 mm displacement amplitude or 10g maximum acceleration. Vibration applied for three 2-hour sessions at 10 – 500 Hz (Capacitor clamped by body). Requirements No leakage of electrolyte or other visible damage. Deviations in capacitance and tanδ from initial measurements must not exceed: ∆ C/C < 5%
Performance Characteristics
Standards
IEC 60384-4 long life grade 40/85/56, in accordance with CECC 30 301–809
Test Method & Performance
Endurance Life Test
Conditions Temperature Test Duration Ripple Current Voltage +105°C 2,000 hours Maximum ripple current specified in table The sum of DC voltage and the peak AC voltage must not exceed the rated voltage of the capacitor Performance
Performance
Capacitance Change Equivalent Series Resistance Leakage Current
The following specifications will be satisfied when the capacitor is tested at +20°C:
≤ 160 V > 160 V Does not exceed 200% of the initial value Does not exceed leakage current limit Within 15% of the initial value Within 10% of the initial value
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
A4025_PEH536 • 9/9/2013
.