Recold JT Series C O O L I N G TOW E R Free Datasheet http://www.nDatasheet.com Recold JT Series Cooling Tower — Construction 2 Recold, the pioneer of Dri-Fan forced draft evaporative coolers, now applies this principal to the cooling of process water. With the fan in the supply air stream, away from the high humidity air leaving the tower, the fan shaft and bearing are assured longer life. SYSTEM The process water enters the spray tree at the top of the unit, is sprayed down onto the heat .

  JT2140   JT2140


Document
Recold JT Series C O O L I N G TOW E R Free Datasheet http://www.nDatasheet.com Recold JT Series Cooling Tower — Construction 2 Recold, the pioneer of Dri-Fan forced draft evaporative coolers, now applies this principal to the cooling of process water. With the fan in the supply air stream, away from the high humidity air leaving the tower, the fan shaft and bearing are assured longer life. SYSTEM The process water enters the spray tree at the top of the unit, is sprayed down onto the heat exchanger surface or “fill”, giving up heat to the counterflowing air before returning to the system from the sump pan. Moist air does not enter the fan assembly, resulting in longer life and fewer service problems. HYDROSPRAY NOZZLES Hydrospray nozzles are made of non-ferrous material, sized and spaced for optimum wetting of fill. The even distribution of spray across the fill material is extremely important in evaporative equipment. ACCESSIBILITY Recold cooling towers are designed for maximum accessibility for inspection and cleaning. Recold patented access doors on both sides of the unit provide ample access to the spray nozzles, fill, eliminators, bleeds and sump pan for service and maintenance. Recold access doors provide a complete air and water tight seal without gaskets or fasteners, and are “quick opening.” CONSTRUCTION Recold cooling towers are constructed of 300 series stainless steel (basin, fill supports and access doors) and heavy gauge hot dipped G-235 galvanized steel per ASTM A-525. BLOWERS A single, slow-speed forward curve blower is used for optimum efficiency and minimum noise. Each blower is balanced to eliminate unit vibration on Recold’s high precision electronic balancing equipment. Large blowers are made from galvanized steel and subject to careful quality control throughout. Fan shafts are coated to prevent corrosion. The blower drives are selected at 150% of rated brake horsepower. Bearings are self-aligning, ball-bearing type, with external lubricating fittings and selected for 2000,000 hour average bearing life. Rugged, OSHA approved, belt guard and screen are provided for protection. Motor is mounted on an adjustable base. INTEGRATED ASSEMBLY Recold cooling towers are completely assembled at the factory and shipped as a unit. FILL High efficiency is accomplished by using a PVC fill design that provides the maximum amount of wetted surface within allowable airside pressure drop. Fill is conveniently sized for easy removal. The cooling tower fill shall be high efficiency, self-extinguishing PVC, a minimum of 40 mils thick. It shall have a flame spread rating of 25 per ASTM standard E-84 and be impervious to rot, decay, fungus or biological attack. DRIFT ELIMINATORS Eliminators are constructed of PVC assembled in removable, easy to handle sections. A three-pass design allows three changes in air flow resulting in decreased drift rates. The use of durable PVC eliminates the corrosion problems associated with galvanized eliminators. TESTING All Recold cooling towers are tested under the close supervision of the Quality Control Department before being released for shipment. Fans are run and spray systems operated to assure quiet, balanced operation without leaks, water carryover or vibration. Nozzles are checked for proper distribution. Use this data for preliminary layouts only. Obtain current drawing from your Marley/Recold sales representative. The UPDATE web-based selection software — available at spxcooling.com — provides JT Series model recommendations based on customer's specific design requirements. Free Datasheet http://www.nDatasheet.com Recold JT Series Cooling Tower — Schematic DIMENSIONS inches A 80 96 1153⁄4 1391⁄2 1391⁄2 1721⁄4 1721⁄4 1841⁄4 208 208 221 2451⁄2 268 B 76 76 77 801⁄4 801⁄4 921⁄2 921⁄2 981⁄2 981⁄2 981⁄2 1181⁄2 1181⁄2 1181⁄2 C note 2 31 37 451⁄4 551⁄2 551⁄2 667⁄8 667⁄8 931⁄4 933⁄8 933⁄8 1001⁄2 1001⁄2 1001⁄2 D 84 102 124 144 144 1801⁄4 1801⁄4 192 217 217 225 248 273 H — — 511⁄4 51 51 713⁄4 713⁄4 841⁄2 961⁄2 961⁄2 80 104 128 J 6 6 6 6 6 6 6 8 8 8 10 10 10 K 53 65 763⁄4 92 92 115 115 115 1391⁄4 1391⁄4 1391⁄2 1641⁄2 188 R 611⁄4 61 65 67 67 71 71 78 78 78 102 102 102 ACCESS DOORS FAR SIDE TOP 1 1 1 1 1 2 2 2 2 2 2 2 2 BOTTOM 1 1 1 1 1 1 1 1 1 1 2 2 2 NEAR SIDE TOP — — 1 1 1 2 2 2 2 2 2 2 2 BOTTOM — — 1 1 1 1 1 1 note 1 1 note 1 1 note 1 2 note 1 2 note 1 2 note 1 SUMP gallons note 4 43 64 95 163 163 248 248 374 454 454 748 880 1012 3 MODEL JT1830 JT2140 JT2550 - JT2565 JT3175 - JT3185 JT31100 JT37110 - JT37130 JT37140 JT40160 - JT40180 JT40215 - JT40240 JT40265 JT49290 - JT49310 JT49340 - JT49360 JT49390 - JT49415 Note  n additional bottom access door is installed on inlet 1 A connection end. 2  Overall width of unit at base rail is C plus 1". 3  Maximum overall height at blower (fan) section is 118". A K ACCESS DOOR ELIMINATOR ACCESS SPRAY HEADER CLEANOUT 4.  Water level at top of overflow stand pipe 5  Discharge duct flange is C minus 3" and K minus 3". C I.


NAS1330 JT2140 JT2550


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)