DatasheetsPDF.com

RP3SLA12 Dataheets PDF



Part Number RP3SLA12
Manufacturers Tyco
Logo Tyco
Description General Purpose Relays
Datasheet RP3SLA12 DatasheetRP3SLA12 Datasheet (PDF)

General Purpose Relays Special Load PCB Relay RP 3 SL I I I I I I 1 pole 16 A, 1 NO contact For high inrush currents, 120 A / 20 ms inrush peak current Mono- or bistable 4 kV / 8 mm coil-contact RoHS compliant (Directive 2002/95/EC) as per product date code 0404 Applications Lighting control, timers, motor control, building automation F0147-A Approvals V REG.-Nr. 3736 (DC versions only), Z E214024 Technical data of approved types on request Contact data Contact configuration Contact set Ty.

  RP3SLA12   RP3SLA12


Document
General Purpose Relays Special Load PCB Relay RP 3 SL I I I I I I 1 pole 16 A, 1 NO contact For high inrush currents, 120 A / 20 ms inrush peak current Mono- or bistable 4 kV / 8 mm coil-contact RoHS compliant (Directive 2002/95/EC) as per product date code 0404 Applications Lighting control, timers, motor control, building automation F0147-A Approvals V REG.-Nr. 3736 (DC versions only), Z E214024 Technical data of approved types on request Contact data Contact configuration Contact set Type of interruption Rated current relay version RP3 / RP7 Rated voltage / max.switching voltage AC Limiting continuous current Maximum breaking capacity AC RP3 / RP7 Limiting making capacity, max 4 s, duty factor 10% peak value, max 20 ms Contact material Mechanical endurance DC-coil bistable coil Rated frequency of operation with / without load Contact Type RP3SL RP3SL ratings Load 16 A, 250 VAC, 70°C, 16 min-1, IEC61810-1 12 A, 250 VAC, 70°C, 16 min-1, IEC61810-1 1 NO single contact micro-disconnection 16 A / 12 A 250/400 VAC 16 A 4000 VA / 3000 VA 25 A 120 A AgSnO2 > 20x106 cycles > 1x 106 cycles 16 / 1200 min-1 Cycles 5x104 1x105 Coil data Coil data, monostable coil Rated coil voltage range Coil power Operative range RTII / RTIII 5...110 VDC typ 520 mW 2/1 Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC c mW 012 12 9.0 1.2 270+10% 533 024 24 18.0 2.4 1100+15% 524 048 48 36.0 4.8 4400+15% 524 060 60 45.0 6.0 6540+15% 550 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request 1 Datasheet Rev. FB1 Issued 2006/02 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. Free Datasheet http://www.datasheetlist.com/ General Purpose Relays Special Load PCB Relay RP 3 SL (Continued) Coil data, bistable coils Rated coil voltage range Coil power Operative range Reset voltage minimum / maximum, % of Urtd Minimum energization duration Maximum energization duration 2 coils 5...24 VDC typ 1,25 W 1 70% / 110% 75% / 120% 20 ms 1 min at < 50% DF 1 coil Coil versions, bistable DC-coil Coil Rated Operate Reset Reset Coil Rated coil code voltage voltage voltage R1 resistance power VDC VDC VDC c/W c mW bistable, 1 coil A05 5 3.7 3.6 39/0.5 21+10% 1190 A12 12 9.0 8.7 220/0.5 115+10% 1252 A24 24 18.0 16.7 820/0.5 460+10% 1252 bistable, 2 coils F12 12 9.0 9.0 105+15% 1371 F24 24 18.0 18.0 460+15% 1252 All figures are given for coil without preenergization, at ambient temperature +23°C, duty factor 20%. Other coil voltages on request Circuit scheme for bistable 1 coil Insulation Dielectric strength coil-contact circuit open contact circuit Clearance / creepage coil-contact circuit Material group of insulation parts Tracking index of relay base Insulation to IEC 60664-1 Type of insulation coil-contact circuit open contact circuit Rated insulation voltage Pollution degree Rated voltage system Overvoltage category 4000 Vrms 2000 Vrms W 8 / 8 mm W IIIa PTI 250 V basic functional 250 V 3 240 V III 2 400 V PCB layout / terminal assignment Bottom view on solder pins Other data RoHS - Directive 2002/95/EC compliant as per product date code 0404 Flammability class according to UL94 V-2 Ambient temperature range RTII - flux proof -40...+70°C RTIII - wash tight -40...+35°C Operate- / release time DC coil typ 8 / 2 ms Operate- / reset time bistable coils typ 6 / 2 ms Bounce time typ 2 ms Vibration resistance (function), opening of closed contact 20 g Shock resistance (destruction) 100 g Category of protection RTII - flux proof, RTIII - wash tight Mounting pcb or on socket Mounting distance 12A / 16A 0 / 3 mm Resistance to soldering heat flux proof version 270 °C / 10 s wash tight version 260°C / 5 s Relay weight 18 g Packaging unit monostable, bistable 1 coil 20 / 500 pcs bistable 2 coils 100 pcs S0163-CR S0163-CS Accessories For monostable and bistable 1 coil version, details see accessories RT Bistable versions: Indicated contact position during or after coil energization with reset voltage. 2-coil versions: Operate A2, A3 Reset A1, A3 b) for 2 coil version only 2 Datasheet Rev. FB1 Issued 2006/02 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. Free Datasheet http://www.datasheetlist.com/ General Purpose Relays Special Load P.


RP3SL024 RP3SLA12 RP3SLA24


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)