DatasheetsPDF.com

5EFM4C Dataheets PDF



Part Number 5EFM4C
Manufacturers Tyco
Logo Tyco
Description Power Entry Module
Datasheet 5EFM4C Datasheet5EFM4C Datasheet (PDF)

CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications M Series XM/ZM UL Recognized CSA Certified VDE Approved VM M Series The M series power entry modules offer the most choices of power entry components and filtering options to fit a specific need. The fully configured M series expands the options of a manufacturer whose products are marketed worldwide. One component, fully assembled and tested, provides the capability of interfacin.

  5EFM4C   5EFM4C


Document
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications M Series XM/ZM UL Recognized CSA Certified VDE Approved VM M Series The M series power entry modules offer the most choices of power entry components and filtering options to fit a specific need. The fully configured M series expands the options of a manufacturer whose products are marketed worldwide. One component, fully assembled and tested, provides the capability of interfacing a multi-voltage power supply to any common voltage or fusing scheme in the world, without modification. •The IEC connector provides an internationally accepted power entry termination, which can be used with a variety of line cords. •The selectable fuseholder allows use of single or dual European fuses, or a single North American fuse. •The optional DPST on/off switch breaks both sides of the line and is labeled with the international I/O markings. •The optional voltage selector provides a convenient means to change transformer primary connection, and it is available in both 2-voltage and 4-voltage configurations. •The series is available with four filter circuits to meet a variety of applications, and convenient connections are provided on unfiltered models to allow wiring of a separate RFI filter. The M series is a family of components offering greater flexibility and cost-effectiveness in the selection of primary power components. Wiring to the modules is accomplished via .110” terminals for labor savings and convenience. Four filter circuits provide a choice of attenuation tailored to specific categories of susceptibility and emissions needs. HM Models – This medical filter provides susceptibility protection without the leakage current associated with line-to-ground capacitors. Designed to allow equipment to meet UL544 for patient care and non-patient care equipment, the HM filter has a maximum leakage current of 2 µA at 120 VAC 60 Hz. See Appendix C for more information on medical applications and UL standards. 124 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. FM Models – General purpose RFI filter designed for susceptibility applications, effectively providing RFI control of line-to-ground noise. The design is compact and meets the very low leakage current requirements of VDE portable equipment as well as (120 Volt) UL544 non-patient medical equipment. XM Models – High performance RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits. ZM Models – Premium RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. Fuse Installation Instructions 1. 2. 3. 4. 5. 6. 7. Remove power cord. Pry door open at socket. Lift and swing door into socket. Lift fuse holder out of housing. Install one (1) AG fuse or two (2) metric fuses*. Replace fuse holder into housing. Swing and snap door back in place. *Install fuses on one side only, do not install both AG and metric fuses at the same time. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com Free Datasheet http://www.datasheet-pdf.com/ CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) M Series Fuse Options European Fusing Arrangement** 1. Insert a pocket screwdriver at point “X” as shown. "X" A Removing the Fuse Holder Power Entry Modules A Section A-A North American Fusing Arrangement** Gently lift UP until the entire door lifts up approximately 1/4" (minimum). Lift Up 2. Once lifted, the door will pivot on it’s hinges and expose the fuse holder. **Install fuses on one side only. Do Not install both AG and Metric fuses at the same time. Voltage Selection To change selected voltage: open cover, using small blade screwdriver or similar tool; set aside cover/fuse block assembly; pull voltage selector card straight out of housing, using indicator pin; orient selector card so that desired voltage is readable at the bottom; orient indicator pin to point up when desired voltage is readable at bottom (note that when indicator pin is fixed, successive voltages are selected by rotating the card 90° clockwise); insert voltage selector card into housing, printed side of card facing forward toward IEC connector and edge containing the desired voltage first; replace cover, and verify that indicator pin shows the desired voltage. Voltage Selector Card Orientation 2 4 3. When the fuse holder is installed in the single fuse position, apply the screwdriver as shown and gently pry up. Use screwdriver as shown, do not use .


5EFM4 5EFM4C 5EFM4S


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)