DatasheetsPDF.com

EC215R Dataheets PDF



Part Number EC215R
Manufacturers Hanna
Logo Hanna
Description (EC214 / EC215) Multi-Range Conductivity Meters Manual
Datasheet EC215R DatasheetEC215R Datasheet (PDF)

Instruction Manual EC214 EC215 • EC215R Multi-Range Conductivity Meters for Laboratories w w w . h a n n a i n s t . c o m Free Datasheet http://www.datasheet PRELIMINARY EXAMINATION Dear Customer, Thank you for choosing a HANNA instruments® product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for correct operation. If you need additional technical information, do not hesitate to e-mail us at tech@.

  EC215R   EC215R


Document
Instruction Manual EC214 EC215 • EC215R Multi-Range Conductivity Meters for Laboratories w w w . h a n n a i n s t . c o m Free Datasheet http://www.datasheet PRELIMINARY EXAMINATION Dear Customer, Thank you for choosing a HANNA instruments® product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for correct operation. If you need additional technical information, do not hesitate to e-mail us at [email protected]. These instruments are in compliance with the directives. Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any damage, notify your dealer. Each meter is supplied complete with: • 4-ring conductivity probe with 1 m (3.3’) cable • HI 76300 for EC 214 • HI 76303 for EC 215 and EC 215R • 12 Vdc adapter • Instruction manual Note: Save all packing material until you are sure that the instrument functions correctly. All defective items must be returned in the original packing with the supplied accessories. TABLE OF CONTENTS PRELIMINARY EXAMINATION ....................................................... 3 GENERAL DESCRIPTION ............................................................... 3 FUNCTIONAL DESCRIPTION EC 214 ............................................. 4 SPECIFICATIONS EC 214 ............................................................. 5 FUNCTIONAL DESCRIPTION EC 215 ............................................. 6 SPECIFICATIONS EC 215 ............................................................. 7 OPERATIONAL GUIDE .................................................................. 8 CALIBRATION ............................................................................ 10 CONDUCTIVITY VS. TEMPERATURE CHART ................................... 13 DETERMINATION OF THE TEMPERATURE COEFFICIENT OF A SOLUTION (EC 215) ..................................... 14 PROBE MAINTENANCE ............................................................... 15 ACCESSORIES ............................................................................ 16 WARRANTY ............................................................................... 18 CE DECLARATION OF CONFORMITY ............................................. 19 GENERAL DESCRIPTION EC 214 and EC 215 are bench top multi-range conductivity meters for the laboratory. Four measurement ranges ensure the highest resolution and precision for your measuring requirements. Single point calibration is performed manually simply by adjusting a knob on the front of the meter. Temperature compensation of the readings is automatic for the EC 215 models, thanks to the temperature sensor incorporated in probe, with userselectable temperature coefficient. With EC 214 the temperature compensation is manual and the temperature value can be also set with a knob. The rugged probe with platinum 4-ring sensor responds faster than conventional stainless steel models and can be also used for measuring highly acidic or alkaline samples, or at high temperature. In addition, the EC 215R model offers analog output of 0 to 5V that represents the full conductivity scale across all 4 ranges. 2 3 Free Datasheet http://www.datasheet-pdf.com/ FUNCTIONAL DESCRIPTION EC 214 SPECIFICATIONS EC 214 0.0 to 199.9 μS/cm / 0 to 1999 μS/cm 0.00 to 19.99 mS/cm / 0.0 to 199.9 mS/cm Resolution 0.1 μS/cm / 1 μS/cm 0.01 mS/cm / 0.1 mS/cm Accuracy (@20°C/68°F) ±1% FS (excluding probe error) Typical EMC Deviation ±1% F.S. Calibration Manual, single point, through front knob Temperature Compensation Manual, 0 to 50°C (32 to 122°F) with β=2%/°C Probe HI 76300, platinum 4-ring sensor, with 1 m (3.3') cable (included) Power Supply 12 Vdc (power adapter included) Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions 240 x 182 x 74 mm (9.4 x 7.1 x 2.9") Weight 1.0 kg (2.2 lb.) Range 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) Liquid Crystal Display (LCD) Conductivity calibration knob 199.9 μS key for range selection 19.99 mS key for range selection 199.9 mS key for range selection 1999 μS key for range selection COND/°C key, to select conductivity reading or temperature setting for manual compensation Temperature setting knob for manual compensation ON/OFF switch Power adapter socket Probe connector 4 5 Free Datasheet http://www.datasheet-pdf.com/ FUNCTIONAL DESCRIPTION EC 215 SPECIFICATIONS EC 215 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) Liquid Crystal Display (LCD) Conductivity calibration knob 199.9 μS key for range selection 19.99 mS key for range selection 199.9 mS key for range selection 1999 μS key for range selection Temperature coefficient setting knob ON/OFF switch Power adapter socket Probe connector Analog output (EC 215R only) 0.0 to 199.9 μS/cm / 0 to 1999 μS/cm 0.00 to 19.99 mS/cm / 0.0 to 199.9 mS/cm Resolution 0.1 μS/cm / 1 μS/cm 0.01 mS/cm / 0.1 mS/cm Accuracy (@20°C/68°F) ±1% F.S. (excluding.


EC215 EC215R A614


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)