Document
CN-A SERIES
5
http://www.DataSheet4U.com/
CN-A_1
CN30A110
CN30A110 Specifications
Voltage Range Input Efficiency(typ) Current Nominal Voltage Maximum Current Maximum Power Voltage Setting Accuracy (*1) Output Maximum Line Regulation (*2) Maximum Load Regulation (*3) Temperature Coefficient Maximum Ripple & Noise (*8) Voltage Adjustable Range (*8) Over Current Protection Remote Sensing Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Environment Vibration Shock Cooling Isolation Withstand Voltage Isolation Resistance Standards Safety Standards Mechanical Weight(typ) Size (W×H×D)
(*9) (*7) (*6) (*4) (*7) (*1) (*1)
DC60 - 160 83 0.34 5 6 12 2.5 30 -/+ 1 20 40 100 -10 / +20 105 - 140 125 - 145 (Inverter shutdown method) Possible Possible (SHORT : ON OPEN : OFF) Possible -40 - +100 (Baseplate) Ambient Temperature min=-40°C -40 - +100 5 - 95 (No Dewdrop) 5 - 95 (No Dewdrop) At No Operating, 10-55Hz (Sweep for 1min.) Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each IEC61373 - Category 1 - Grade B 196.1m/s²
http://www.DataSheet4U.com/
84 15 2 24 1.3 31.2 60 120 0.02%/°C 150 -/+ 10 240 96 192
48 96
Over Voltage Protection (*5)(*7) Function Remote ON/OFF Control (*7)
IEC61373 - Category 1 - Grade B Conduction Cooled
Input-Baseplate : 1.5kVAC (20mA), Input-Output : 3.0kVAC for 1min. Output-Baseplate : 500VAC for 1min. (20mA). More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC Approved by UL60950-1, CSA60950-1, EN60950-1 70 36.8 x 12.7 x 57.9 (Refer to Outline Drawing)
*1. At 110VDC and maximum output current. (Baseplate Temperature = +25°C) *2. 60 - 160VDC, Constant load. *3. No Load - Full Load, Constant input voltage. *4. 5V delay shutdown when left in OCP condition, with the output voltage less than the LVP level. 12V, 15V and 24V constant current limiting with automatic recovery. LVP reset : Line off or Control off. *5. OVP reset : Line off or Control off. *6. Rating - Refer to Derating Curve on the next page. - Load(%) is percent of maximum output current. - Refer to Instruction Manual. *7. Refer to Instruction Manual. *8. External components are needed for operation. (Refer to Basic Connection and Instruction Manual.) *9. This specification applies to power supply module as stand-alone.
CN-A_2
CN30A110
CN30A110 Outline Drawing
C L
57.9±0.5
-V -Vin -S 15.24±0.25 12.7±0.25 7.62±0.25 36.8±0.5 28±0.25
C L
CNT
TRM +S
+Vin
+V
49.7±0.5
http://www.DataSheet4U.com/
Output Derating
12.7±0.5
5±0.5
CN-A_3
CN50A110
CN50A110 Specifications
Voltage Range Input Efficiency(typ) Current Nominal Voltage Maximum Current Maximum Power Voltage Setting Accuracy (*1) Output Maximum Line Regulation (*2) Maximum Load Regulation (*3) Temperature Coefficient Maximum Ripple & Noise (*8) Voltage Adjustable Range (*8) Over Current Protection Remote Sensing Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Enviro.