MSA_(M)D-3W & MSB_(M)D-3W Series
3W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DIP DC-DC CONVERTER
multi-country patent protection
FEATURES ● Wide (2:1) input range ● Efficiency up to 82% ● Operating temperature: -40°C ~ +85°C ● 1500VDC isolation ● Short circuit protection(Automatic recovery) ● Internal SMD construction ● No heat sink required ● No external component required ● UL94-V0 package ● Industry standard pinout ● MTBF>1,000,000 hours ● RoHS Compliance
PRODUCT PROGRAM
Input Part Number MSA0505(M)D-3W MSA0512(M)D-3W MSA0515(M)D-3W MSB0505(M)D-3W MSB0509(M)D-3W MSB0512(M)D-3W MSB0515(M)D-3W MSA1205(M)D-3W MSA1212(M)D-3W MSA1215(M)D-3W MSB1205(M)D-3W MSB1209(M)D-3W 12 9-18 22 5 4.5-9 11 Voltage (VDC) Nominal Range Voltage Max* (VDC) ±5 ±12 ±15 5 9 12 15 ±5 ±12 ±15 5 9 12 15 24 ±5
www.DataSheet.net/
Output Current (mA) Max. ±300 ±125 ±100 600 333 250 200 ±300 ±125 ±100 600 333 250 200 125 ±300 ±125 ±100 909 600 333 250 200 125 ±300 ±125 ±100 909 600 333 250 200 125 Min. ±30 ±12 ±10 60 33 25 20 ±30 ±12 ±10 60 33 25 20 12 ±30 ±12 ±10 90 60 33 25 20 12 ±30 ±12 ±10 90 60 33 25 20 12 68 72 73 68 70 72 73 76 79 80 76 78 80 81 82 76 80 81 74 76 78 81 80 82 76 80 81 74 76 78 81 80 82 UL UL UL UL UL Efficiency Certificate (%, Typ)
APPLICATIONS
The MSA_(M)D-3W &MSB_(M)D-3W Series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is wide range (Voltage range≤ 2:1); 2) Where isolation is necessary between input and output(Isolation voltage≤ 1500VDC); 3) Where the regulation of the output voltage and the output ripple noise are dem anded.
MSB1212(M)D-3W MSB1215(M)D-3W MSB1224(M)D-3W MSA2405(M)D-3W MSA2412(M)D-3W MSA2415(M)D-3W MSB2403(M)D-3W MSB2405(M)D-3W MSB2409(M)D-3W MSB2412(M)D-3W MSB2415(M)D-3W MSB2424(M)D-3W MSA4805(M)D-3W MSA4812(M)D-3W MSA4815(M)D-3W 24 18-36 40
±12 ±15 3.3 5 9 12 15 24 ±5 ±12 ±15 3.3
MODEL SELECTION
MSB4803(M)D-3W MSB4805(M)D-3W
Rated Power Package Style Output Voltage Input Voltage Product Series
MSA2405MD-3W
48
36-72
80
5 9 12 15 24
MSB4809(M)D-3W MSB4812(M)D-3W MSB4815(M)D-3W MSB4824(M)D-3W
* Input voltage over it may cause permanent damage to the device. Note: Metal package style’s series is MSA_MD-3W & MSB_MD-3W.
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Hangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax: 86-20-38601272 http://www.mornsun-power.com
ISOLATION SPECIFICATIONS
Item Isolation voltage Isolation resistance Isolation capacitance Test conditions Tested for 1 minute and 1mA max Test at 500VDC Input/Output Min. 1500 1000 80 Typ. Max. Units VDC MΩ pF
The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. MSA_((M)D-3W&MSB_(M)D-3W A/2-2009 Page 1 of 3
Datasheet pdf - http://www.DataSheet4U.co.kr/
OUTPUT SPECIFICATIONS
Item Output power Positive voltage accuracy Load regulation Line regulation Temperature drift(Vout) Ripple & Noise** Switching frequency Test conditions See below products program Refer to recommended circuit From 10% to 100% load Input voltage from low to high Refer to recommended circuit 20MHz Bandwidth 100% load, nominal input voltage 50 300 Min. 0.3 ±1 ±3 ±0.5 ±0.2 Typ. Max. 3 ±3 ±5 ±1* ±0.5 ±0.03 100 %/ °C mVp-p KHz % Units W
TYPICAL CHARACTERISTICS
Negative voltage accuracy Refer to recommended circuit
*Dual output models unbalanced load: ±5%. **Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section, application notes.
100
Operating Temp.( C )
COMMON SPECIFICATIONS
Item Storage humidity Operating temperature Storage temperature Temp. rise at full load Lead temperature No-load Power consumption Cooling Short circuit protection Case material MTBF Weight Free air convection Continuous, Automatic Recovery D: Plastic (UL94-V0); MD: Steel, Nickel Coated 1000 15 K hours 1.5mm from case for 10 seconds 0.2 -40 -55 15 300 W Test Conditions Min. Typ. Max. 95 85 125 °C Units %
RECOMMENDED CIRCUIT
Vin
Cin
+Vout
DC
DC
0V -Vout
GND Single Output Vin
Cin
+Vout
DC
DC
0V
GND
(Figure 1) g
Input Current(A)
Ip
APPLICATION NOTE
Requirement On Output Load In order to ensure the product operate efficiently and reliably, in addition to a max load
www.DataSheet.net/
Input Voltage Range
(namely full load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading, or contact o.