Description Current Sensors
Datasheet SICDS50V6 DatasheetSICDS50V6 Datasheet (PDF)

  SICDS50V6 Current Sensors Features  Hall effect measuring principle  Galvanic isolation between primary and secondary circuit  Low power consumption  Extended measuring range  Insulated plastic case recognized according to UL 94-V0 I PN = 50A Advantages        Very good linearity Excellent accuracy Low temperature drift Wide frequency bandwidth Optimized response time No insertion losses High immunity against external Interference  Excellent performance and price Industrial app.

  SICDS50V6   SICDS50V6


Document
  SICDS50V6 Current Sensors Features  Hall effect measuring principle  Galvanic isolation between primary and secondary circuit  Low power consumption  Extended measuring range  Insulated plastic case recognized according to UL 94-V0 I PN = 50A Advantages        Very good linearity Excellent accuracy Low temperature drift Wide frequency bandwidth Optimized response time No insertion losses High immunity against external Interference  Excellent performance and price Industrial applications       AC variable speed drives Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding applications Static converters for DC motor drives Switched-Mode Power Supplies (SMPS) www.DataSheet.net/ Type TYPES OF PRODUCTS Primary nominal Primary current Measuring resistance (@70℃) current measuring range R M (Ω) r. m. s I PN (A) I P (A) 10~100 with±12V@±50Amax with±12V@±70Amax with±15V@±50Amax with±15V@±70Amax 50 0~±70 10 ~ 50 50~160 50 ~ 90 SICDS50V6 General Description For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit) 1 V2.00 May 1, 2012 Datasheet pdf - http://www.DataSheet4U.co.kr/   SICDS50V6 Current Sensors Parameters Table PARAMETERS Supply voltage(±5%) Current consumption Secondary nominal r.m.s. current Conversion ratio Linearity SYMBOL VC IC I SN KN εL % UNIT V mA mA VALUE ±12…15 10(@±15)+I s 50 1:1000 <±0.15 <±0.65 Accuracy XG % <±0.90 Offset current Thermal drift of Io Response time di/dt accurately followed Frequency bandwidth (1) Ambient operating temperature Ambient storage temperature Secondary coil resistance R. m. s voltage for AC isolation test Impulse withstand voltage 1.2/50us Creepage distance Clearance distance Comparative Tracking Index IO I OT tr d i /dt BW TA TS Rs mA mA µS A/µS kHz General data ℃ ℃ Ω -40 ~ +85 -40 ~ +90 80 @ T A = 70°C <±0.20 Typ ±0.1 ±0.2 www.DataSheet.net/ CONDITIONS Electrical data @I PN Accuracy - Dynamic performance data @ I PN , V C = ±15V, T A = 25°C @ I PN , V C = ±12…15V, T A = 25°C @ I P = 0,T A = 25°C Max ±0.6 ±1.0 <1 >200 DC~200 @-1dB @ I P = 0,-25°C~+85°C @ I P = 0,-40°C~-25°C @ 90% of I PN step Isolation characteristics Vd Vw dCp dCI CTI KV KV mm mm 2.5 5.7 5 5 175 Group IIIa @50Hz, 1 min Notes: Please refer to derating curves in the technical file to avoid excessive core heating at high frequency. 2 V2.00 May 1, 2012 Datasheet pdf - http://www.DataSheet4U.co.kr/   SICDS50V6 Current Sensors Dimensions SICDS50V6 (in mm. 1 mm = 0.0394 inch) www.DataSheet.net/ Instructions of use 1 When the test current passes through the sensor, you can get the size of the output current. (Warning: wrong connection may lead to sensors damage.) 2 Is is positive when Ip flows in the direction of the arrow. 3 In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device. 4 According to user needs, different rated input currents and output currents of the sensors can be customized. 3 V2.00 May 1, 2012 Datasheet pdf - http://www.DataSheet4U.co.kr/   SICDS50V6 Current Sensors RESTRICTIONS ON PRODUCT USE The information contained herein is subject to change without notice. SEC ELECTRONICS INC. (for short SEC) exerts the greatest possible effort to ensure high quality and reliability. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing SEC products, to comply with the standards of safety in making a safe design for the entire system, including redundancy, fire-prevention measures, and malfunction prevention, to prevent any accidents, fires, or community damage that may ensue. In developing your designs, please ensure that SEC products are used within specified operating ranges as set forth in the most recent SEC products specifications. The SEC products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These SEC products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of SEC products listed in this document shall be made at the customer’s own risk. www.DataSheet.net/   4 V2.00 May 1, 2012 Datasheet pdf - http://www.DataSheet4U.co.kr/ .


SICDS100V6 SICDS50V6 SICF3SV2


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)