Safety Relay SR2M
www.DataSheet.co.kr
General Purpose Relays
Safety Relay SR2M
I I I I I
2 pole safety relay with either 1NO+1NC or 2C...
Description
www.DataSheet.co.kr
General Purpose Relays
Safety Relay SR2M
I I I I I
2 pole safety relay with either 1NO+1NC or 2CO contacts Forcibly guided contacts according to EN 50205 Rated current 6 A 6 kV surge resistance between poles RoHS compliant (Directive 2002/95/EC) as per product date code 0407
Applications Emergency shut-off, machine control, elevator and escalator control, light barrier control
F0188-C
Approvals
V REG.-Nr. 116064, Z E214024, T 968/EZ 111.00/01 Technical data of approved types on request
Contact data
Contact configuration Contact set Type of interruption Rated current Rated voltage / max.switching voltage AC Maximum breaking capacity AC Utilization class (AC-15) acc. IEC 60947-5-1 NO contact NC contact Contact material Minimum contact load Contact resistance 1 NO contact and 1 NC contact or 2 CO contacts 1) single contact, forcibly guided 1 NC + 1NO: type A according to EN 50205 2 CO: type B according to EN 50205 micro disconnection 6A 240 / 400 VAC 1500 VA
Ie 3 A / Ue 250 VAC (inrush 30 A) Ie 1.5 A / Ue 250 VAC (inrush 15 A) AgNi 10 mA / 5 V w 100 mOhm / 1 A / 24 VDC w 20 Ohm / 10 mA / 5 VDC Mechanical endurance 10x106 cycles Rated frequency of operation with / without load 6 min-1 / 300 min-1
1
) According EN50205 only 1NO / 1NC (11-14 and 22-21 or 12-11 and 21-24) shall be used as forcibly guided contacts.
Coil data
Rated coil voltage range DC coil Coil power DC coil Operative range 5...110 VDC appr. 700 mW 2
Coil versions, DC-coil Coil Rated O...