DatasheetsPDF.com

900-XC6DT2 Dataheets PDF



Part Number 900-XC6DT2
Manufacturers MTU Onsite Energy
Logo MTU Onsite Energy
Description DIESEL ENGINE-GENERATOR SET
Datasheet 900-XC6DT2 Datasheet900-XC6DT2 Datasheet (PDF)

A tognum Group Brand DIESEL ENGINE-GENERATOR SET 900-XC6DT2 900 ekW  60 Hz  Standby /  /  800 ekW / 60 Hz / Prime 208 - 4160V System Ratings Standby Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* Temp Rise Connection 208V** 3 0.8 60 900 1125 3123 2600 741RSL4045 130°C/27°C 12 LEAD LOW WYE 240V** 3 0.8 60 900 1125 2706 2600 741RSL4045 130°C/27°C 12 LEAD HI DELTA 480V** 3 0.8 60 900 1125 1353 2600 574RSL4038 130°C/27°C 4 .

  900-XC6DT2   900-XC6DT2


Document
A tognum Group Brand DIESEL ENGINE-GENERATOR SET 900-XC6DT2 900 ekW  60 Hz  Standby /  /  800 ekW / 60 Hz / Prime 208 - 4160V System Ratings Standby Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* Temp Rise Connection 208V** 3 0.8 60 900 1125 3123 2600 741RSL4045 130°C/27°C 12 LEAD LOW WYE 240V** 3 0.8 60 900 1125 2706 2600 741RSL4045 130°C/27°C 12 LEAD HI DELTA 480V** 3 0.8 60 900 1125 1353 2600 574RSL4038 130°C/27°C 4 LEAD WYE 600V** 3 0.8 60 900 1125 1083 2850 574RSS4280 125°C/40°C 4 LEAD WYE 4160V 3 0.8 60 900 1125 156 1950 741FSM4360 130°C/27°C 6 LEAD WYE Prime Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* www.DataSheet4U.com Temp Rise Connection 208V 3 0.8 60 800 1000 2776 2600 741RSL4045 105°C/40°C 12 LEAD LOW WYE 240V 3 0.8 60 800 1000 2406 2600 741RSL4045 105°C/40°C 12 LEAD HI DELTA 480V 3 0.8 60 800 1000 1203 2600 574RSL4037 105°C/40°C 12 LEAD HI WYE 600V 3 0.8 60 800 1000 962 2850 574RSS4280 105°C/40°C 4 LEAD WYE 4160V 3 0.8 60 800 1000 139 1950 741FSM4360 105°C/40°C 6 LEAD WYE * The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration. ** UL2200 Offered 2 // /  / 900-XC6DT2 Facts //  //  //  //  //  //  //  //  //  //  EPA Tier 2 Certified Engine-Generator Set Tested to ISO 8528-5 for Transient Response UL2200, CSA Listing Offered Accepts Rated Load in One Step Per NFPA 110, Level 1 All engine-generator sets are prototype and factory tested MTU Onsite Energy is a single source supplier Global Product Support 2 Year Standard Warranty Custom Design for Any Application 16V-2000 G84 Diesel Engine - 31.8 Liter Displacement - Electronic Unit Pump Injection - 4-Cycle //  //  //  //  Complete Range of Accessories Permanent Magnet Generator (PMG) - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings Digital Control Panel(s) - UL Recognized, , NFPA 110 - Complete System Metering - LCD Display Cooling System - Integral Set-Mounted - Engine Driven Fan STANDARD EQUIPMENT //  Engine Brushless Alternator with Brushless Pilot Exciter 4 Pole, Rotating Field 130°C Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-Phase Voltage Sensing ±.25% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content Air Cleaners Oil Pump Full Flow Oil Filter Jacket Water Pump Inter Cooler Water Pump Thermostats Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 24V Governor – Electric Isochronous Base - Structural Steel SAE Flywheel & Bell Housing Charging Alternator - 24V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine //  Digital Control Panel(s) //  Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting www.DataSheet4U.com Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator 16 Programmable Contact Inputs 7 Contact Outputs UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA110 Level Compatible 3 // /  / 900-XC6DT2 Application data //  Engine MTU Detroit Diesel 16V-2000 G84 4-Cycle 16-V 1,943 (31.8) 5.1 (13) 5.9 (15) 16:1 1,800 ADEC 1,495 (1,115) 1,354 (1,010) ±.25% 60 Hz Dry //  Fuel Consumption STANDBY 65.2 (247) 51.3 (194) 33.4 (126) PRIME 60.2 (228) 46 (174) 30.5 (115) Manufacturer Model Type Arrangement Displacement: Cu In (lit) Bore: in (cm) Stroke: in (cm) Compression Ratio Rated RPM Engine Governor Max Power: Standby: bhp (kWm) Max Power: Prime: bhp (kWm) Regulation Frequency Air Cleaner At 100% of Power Rating: gal/hr (lit/hr) At 75% of Power Rating: gal/hr( lit/hr) At 50% of Power Rating: gal/hr (lit/hr) //  Cooling - Radiator System PRIME 122 (50) 0.5 (0.12) 220 (833) 68 (258) 23,317 (410) 14,786 (260) 5,258 (92.5) //  Liquid Capacity (Lubrication) 26.9 (102) 34.3 (130) 5.3 (20) 105.6 (400) STANDBY Ambient Capacity of Radiator: °F (°C) 122 (50) Max. Restriction of Cooling Air, Intake, and Discharge Side of Rad.: in. H20 (kPa) 0.5 (0.12) Water Pump Capacity: gpm (lit/min) 220 (833) After Cooler Pump Capacity: gpm (lit/min) 68 (258) Heat Rejection to Coolant: BTUM (kW) 25,023 (440) Heat Rejection to After Cooler: BTUM (kW) 16,492 (290) Heat Radiated to Ambient: BTUM (kW) 5,538 (97) Tot.


85500 900-XC6DT2 BTMS


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)