DIESEL ENGINE-GENERATOR SET
A tognum Group Brand
DIESEL ENGINE-GENERATOR SET 40-JC6DT3 40 ekW 60 Hz Standby
/ / 35 ekW / 60 Hz / Prime
208 -...
Description
A tognum Group Brand
DIESEL ENGINE-GENERATOR SET 40-JC6DT3 40 ekW 60 Hz Standby
/ / 35 ekW / 60 Hz / Prime
208 - 600V
System Ratings
Standby
Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V** 1 1.0 60 40 40 167 63 361CSL1601 130°C/27°C
12 LEAD ZIG-ZAG
240V** 1 1.0 60 40 40 167 99 284CSL1550 130°C/27°C 4 LEAD
208V** 3 0.8 60 40 50 139 85 284CSL1542 130°C/27°C
12 LEAD LOW WYE
240V** 3 0.8 60 40 50 120 132 284CSL1542 130°C/27°C
12 LEAD HI DELTA
480V** 3 0.8 60 40 50 60 122 284CSL1508 130°C/27°C 12 LEAD HI WYE
600V** 3 0.8 60 40 50 48 92 361PSL1632 125°C/40°C 4 LEAD WYE
Prime
Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* www.DataSheet4U.com Temp Rise Connection 240V 1 1.0 60 35 35 146 102 361CSL1601 105°C/40°C
12 LEAD ZIG-ZAG
240V 1 1.0 60 35 35 146 102 284CSL1550 105°C/40°C 4 LEAD
208V 3 0.8 60 35 43.75 121 100 284CSL1542 105°C/40°C
12 LEAD LOW WYE
240V 3 0.8 60 35 43.75 105 100 284CSL1542 105°C/40°C
12 LEAD HI DELTA
480V 3 0.8 60 35 43.75 53 133 284CSL1508 105°C/40°C 12 LEAD HI WYE
600V 3 0.8 60 35 43.75 42 92 361PSL1632 105°C/40°C 4 LEAD WYE
* The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration. ** UL2200 Offered