www.DataSheet4U.com FERROXCUBE DATA SHEET EP13 EP cores and accessories Supersedes data of September 2004 2008 Sep 01 www.DataSheet4U.com Ferroxcube EP cores and accessories CORE SETS Effective core parameters SYMBOL Σ(I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of core set VALUE 1.24 472 24.2 19.5 14.9 ≈ 4.7 UNIT mm−1 mm3 mm mm2 mm2 g 0 13 0.3 handbook, halfpage EP13 0 4.5 0.3 0 9 0.4 2.4 0.1 MGC186 ;;; ;;; ;;; 9.

  EP13   EP13


Document
www.DataSheet4U.com FERROXCUBE DATA SHEET EP13 EP cores and accessories Supersedes data of September 2004 2008 Sep 01 www.DataSheet4U.com Ferroxcube EP cores and accessories CORE SETS Effective core parameters SYMBOL Σ(I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of core set VALUE 1.24 472 24.2 19.5 14.9 ≈ 4.7 UNIT mm−1 mm3 mm mm2 mm2 g 0 13 0.3 handbook, halfpage EP13 0 4.5 0.3 0 9 0.4 2.4 0.1 MGC186 ;;; ;;; ;;; 9.7 0.6 0 0 12.8 0.6 9 0.4 0 Dimensions in mm. Fig.1 EP13 core set. Core sets for filter applications Clamping force for AL measurements, 30 ±10 N. GRADE 3B46 AL (nH) 2150 ±25% µe ≈ 2090 AIR GAP (µm) ≈0 TYPE NUMBER EP13-3B46 Core sets for general purpose transformers and power applications Clamping force for AL measurements, 30 ±10 N. GRADE 3C81 AL (nH) 40 ±3% 63 ±3% 100 ±3% 160 ±3% 250 ±5% 1700 ±25% 3C91 3C94 1700 ±25% 40 ±3% 63 ±3% 100 ±3% 160 ±3% 250 ±5% 1650 ±25% 2008 Sep 01 µe ≈ 40 ≈ 62 ≈ 99 ≈ 158 ≈ 247 ≈ 1680 ≈ 1680 ≈ 40 ≈ 62 ≈ 99 ≈ 158 ≈ 247 ≈ 1630 693 TOTAL AIR GAP (µm) ≈ 1000 ≈ 540 ≈ 300 ≈ 170 ≈ 100 ≈0 ≈0 ≈ 1000 ≈ 540 ≈ 300 ≈ 170 ≈ 100 ≈0 TYPE NUMBER EP13-3C81-E40 EP13-3C81-A63 EP13-3C81-A100 EP13-3C81-A160 EP13-3C81-A250 EP13-3C81 EP13-3C91 EP13-3C94-E40 EP13-3C94-A63 EP13-3C94-A100 EP13-3C94-A160 EP13-3C94-A250 EP13-3C94 www.DataSheet4U.com Ferroxcube EP cores and accessories AL (nH) 1500 ±25% 40 ±3% 63 ±3% 100 ±3% 160 ±3% 250 ±5% 1325 ±25% 3F35 1100 ±25% TOTAL AIR GAP (µm) ≈0 ≈ 1000 ≈ 540 ≈ 300 ≈ 170 ≈ 100 ≈0 ≈0 EP13 GRADE 3C96 3F3 µe ≈ 1480 ≈ 40 ≈ 62 ≈ 99 ≈ 158 ≈ 247 ≈ 1310 ≈ 1090 TYPE NUMBER EP13-3C96 EP13-3F3-E40 EP13-3F3-A63 EP13-3F3-A100 EP13-3F3-A160 EP13-3F3-A250 EP13-3F3 EP13-3F35 Core sets of high permeability grades Clamping force for AL measurements, 30 ±10 N. GRADE 3E27 3E5 3E55 AL (nH) 4600 ± 25% 7000 +40/-30% 100 ±3% 160 ±3% 250 ±5% 315 ±5% 400 ±8% 630 ±15% 7000 +40/-30% 3E6 8500 +40/-30% µe ≈ 4540 ≈ 6900 ≈ 99 ≈ 158 ≈ 247 ≈ 311 ≈ 395 ≈ 622 ≈ 6900 ≈ 8400 AIR GAP (µm) ≈0 ≈0 ≈ 310 ≈ 180 ≈ 110 ≈ 80 ≈ 65 ≈ 40 ≈0 ≈0 TYPE NUMBER EP13-3E27 EP13-3E5 EP13-3E55-A100 EP13-3E55-A160 EP13-3E55-A250 EP13-3E55-A315 EP13-3E55-A400 EP13-3E55-A630 EP13-3E55 EP13-3E6 2008 Sep 01 694 www.DataSheet4U.com Ferroxcube EP cores and accessories Properties of core sets under power conditions B (mT) at GRADE H = 250 A/m; f = 25 kHz; T = 100 °C ≥315 ≥315 ≥320 ≥340 ≥300 ≥315 f = 25 kHz; ˆ = 200 mT; B T = 100 °C ≤ 0.1 − − − − − CORE LOSS (W) at f = 100 kHz; ˆ = 100 mT; B T = 100 °C − ≤ 0.03(1) ≤ 0.04 ≤ 0.03 − ≤ 0.05 f = 100 kHz; ˆ = 200 mT; B T = 100 °C − ≤ 0.17 (1) ≤ 0.22 ≤ 0.17 − − EP13 f = 400 kHz; ˆ = 50 mT; B T = 100 °C − − − ≤ 0.075 ≤ 0.04 ≤ 0.1 3C81 3C91 3C94 3C96 3F35 3F3 Properties of core sets under power conditions (continued) B (mT) at GRADE H = 250 A/m; f = 25 kHz; T = 100 °C ≥315 ≥315 ≥320 ≥340 ≥300 ≥315 f = 500 kHz; ˆ = 50 mT; B T = 100 °C − − − ≤ 0.15 ≤ 0.06 − CORE LOSS (W) at f = 500 kHz; ˆ = 100 mT; B T = 100 °C − − − − ≤ 0.45 − f = 1 MHz; ˆ = 30 mT; B T = 100 °C − − − − − − f = 3 MHz; ˆ = 10 mT; B T = 100 °C − − − − − − 3C81 3C91 3C94 3C96 3F35 3F3 Note 1. Measured at 60 °C. 2008 Sep 01 695 www.DataSheet4U.com Ferroxcube EP cores and accessories COIL FORMERS General data PARAMETER Coil former material Pin material Maximum operating temperature Resistance to soldering heat Solderability SPECIFICATION EP13 phenolformaldehyde (PF), glass-reinforced, flame retardant in accordance with “UL 94V-0” ; UL file number: E41429(M) copper clad steel, tin (Sn) plated 180 °C, “IEC 60085”, class H “IEC 60068-2-20” , Part 2, Test Tb, method 1B: 350 °C, 3.5 s “IEC 60068-2-20” , Part 2, Test Ta, method 1: 235 °C, 2 s handbook, full pagewidth 2.54 13.6 max. 9.5 ± 0.1 4.6 ± 0.1 0.6 13.6 max. 8.9 ± 0.1 7.6 min. 0.6 2.5 2.7 1 3.8 0.8 ∅0.6 10.16 5.08 10.16 Dimensions in mm. 0 5.8 − 0.1 CBW618 1 +0.15 0 Fig.2 EP13 coil former; 10-pins. Winding data and area product for 10-pins EP13 coil former NUMBER OF SECTIONS 1 2 WINDING AREA (mm2) 13.6 2 × 6.1 MINIMUM WINDING WIDTH (mm) 7.6 2 × 3.4 AVERAGE LENGTH OF TURN (mm) 23.8 23.8 AREA PRODUCT Ae x Aw (mm4) 265 2 x 119 TYPE NUMBER CSH-EP13-1S-10P CSH-EP13-2S-10P 2008 Sep 01 696 www.DataSheet4U.com Ferroxcube EP cores and accessories General data CSHS-EP13-1S-10P-T PARAMETER Coil former material Pin material Maximum operating temperature Resistance to soldering heat Solderability SPECIFICATION EP13 phenolformaldehyde (PF), glass-reinforced, flame retardant in accordance with “UL 94V-0”; UL file number E41429 (M) copper-clad steel, tin (Sn) plated 155 °C, “IEC 60085”, class F “IEC 60068-2-20” , Part 2, Test Tb, method 1B, 350 °C, 3.5 s “IEC 60068-2-20”, Part 2, Test Ta, method 1, 235 °C, 2 s 9.5 −0.1 5.8 −0.1 4.6 +0.1 8.9 −0.1 7.5 min. 2.8 handbook, full pagewidth 9.95 max. 10.5 0.7 5 10 CBW505 0.35 1.8 11.85 15.1 max. 1.8 2.5 1.6 13.1 max. Dimensions in mm. Fig.3 EP13 coil former. Winding data and area product for EP13 coil forme.


EM680FV8AU EP13 EP13


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)