DatasheetsPDF.com

H5S Dataheets PDF



Part Number H5S
Manufacturers Omron
Logo Omron
Description Digital Time Switch
Datasheet H5S DatasheetH5S Datasheet (PDF)

Digital Time Switch H5S Easier, More Convenient Time Switches, with New 4-circuit Output and Yearly Models in Addition to 2-circuit Weekly Models • Independent Day Keys provide easier operation. • Temporary holiday setting function makes it easy to turn OFF output for holidays and non-operating days. • Settings can be made even with the Time Switch turned OFF. • Test mode enables easy program checking. • Complies with EMC Directives, UL/CSA, and other safety standards. • Includes summer time (D.

  H5S   H5S


Document
Digital Time Switch H5S Easier, More Convenient Time Switches, with New 4-circuit Output and Yearly Models in Addition to 2-circuit Weekly Models • Independent Day Keys provide easier operation. • Temporary holiday setting function makes it easy to turn OFF output for holidays and non-operating days. • Settings can be made even with the Time Switch turned OFF. • Test mode enables easy program checking. • Complies with EMC Directives, UL/CSA, and other safety standards. • Includes summer time (DST) adjustment. Yearly models also offer automatic switching to DST. • Set value can be changed both upward and downward for speedier setting. • Integrated temperature compensation circuit helps keep accurate time over a wide temperature range. (See note 1.) • Includes time counter and total counter functions with alarm indicator. (See note 2.) • Bank function allows program switching by an external input. (See note 3.) • New 4-circuit output models with a compact, 72 × 72-mm DIN size added to the series. Note: 1. Available only on yearly models. 2. Available only on 2-circuit models. 3. Available only on weekly models. www.DataSheet4U.com CSM_H5S_DS_E_4_1 Features Easier and More Convenient to Use ■ Simple Setting Independent Day Keys make setting easy. Up/down set value changing for speedy setting. Temporary holidays (non-operating days) are also easy to set. Weekly models: Specify the day. Yearly models: Specify the date. Time Adjustment Function (See note.) The time can be set to 00 min 00 s by using an external input. The times on multiple Time Switches can also be easily synchronized. Synchronized! ■ Convenient Functions Time Counter/Total Counter Functions (See note.) This function makes it possible to monitor the total time that a load has been applied, or the total number of operating cycles. It allows the Time Switch to be used for managing maintenance. Master Slave Slave Note: Equipped on 2-circuit models. With alarm indicator Shows total lamp ON time 1 H5S www.DataSheet4U.com More Applications on New Series Models Yearly Models Automatic Program Switching by Seasons The yearly operation can be set to automatically change the weekly program depending on the season. (See note.) Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb 4-circuit Models Space-saving, Economical 4-circuit Models Added to the Series The new 4-circuit models are 72 × 72-mm DIN size. Their spacesaving size allows use in more applications. Spring Summer Summer 19:00 ON 22:00 OFF Autumn Autumn 18:00 ON 21:00 OFF Winter Winter 17:00 ON 21:00 OFF Spring Season (See note 2.) Program 17:30 ON example 21:00 OFF Control all four floors with a single unit. Note: Up to four seasons can be set for 4-circuit models, and up to two seasons for 2-circuit models. Temperature Compensation Circuit Maintains Accurate Time A temperature compensation circuit is provided in the yearly models to maintain accurate time keeping even when the ambient temperature varies greatly. This ensures precise operation with minimal time lags all year round, regardless of temperature changes. Model Number Structure ■ Model Number Legend Note: This model number legend includes combinations that are not available. Please check the “List of Models” for availability. H5S- @@@@@ - @ 1 2 3 4 5 6 4. Number of outputs 2: 2 circuits 4: 4 circuits 5. Supply voltage None: 100 to 240 VAC D: 24 VDC 6. Time accuracy None: Standard X: With temperature compensation 1. Control cycle W: Weekly Y: Yearly 2. Mounting method None: Flush mounting F: Surface mounting/track mounting 3. Panel language B: English A: Japanese 2 H5S www.DataSheet4U.com Ordering Information ■ List of Models Control cycle Weekly Number of outputs 2 circuits Mounting method Flush mounting Surface mounting/ track mounting Yearly 2 circuits Flush mounting Surface mounting/ track mounting 4 circuits Flush mounting Surface mounting/ track mounting Supply voltage 100 to 240 VAC 24 VDC 100 to 240 VAC 24 VDC 100 to 240 VAC 24 VDC 100 to 240 VAC 24 VDC 100 to 240 VAC 24 VDC 100 to 240 VAC 24 VDC Models H5S-WB2 H5S-WB2D H5S-WFB2 H5S-WFB2D H5S-YB2-X H5S-YB2D-X H5S-YFB2-X H5S-YFB2D-X H5S-YB4-X H5S-YB4D-X H5S-YFB4-X H5S-YFB4D-X ■ Accessories (Order Separately) Name Protective Cover Track Mounting Base Large Terminal Cover (in pairs) Y92A-72C Y92F-90 Y92A-72H Model Specifications ■ Ratings Item Rated supply voltage Operating voltage range Power consumption Control Number of circuits outputs Circuits Capacity Weekly 2-circuit Models (H5S-W@2) AC: 85% to 110% rated supply voltage DC: 85% to 120% rated supply voltage Approx. 2.9 VA at 264 VAC 60 Hz Approx. 3.2 VA at 264 VAC 60 Hz Approx. 3.5 VA at 264 VAC 60 Hz Approx. 0.8 W at 28.8 VDC Approx. 0.9 W at 28.8 VDC Approx. 1.0 W at 28.8 VDC SPST-NO × 2 circuits Power supply circuit and other (no-voltage) circuit 3 A at 250 VAC 2 A at 250 VAC (cosφ = 0.4) SPST-NO × 4 circuits Yearly 2-circuit Models (H5S-Y@2) Yearly 4-circuit Models (H5S-Y@4) 100 to 240 VAC (50/60 Hz.


G3PF H5S K3HB-H


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)