DatasheetsPDF.com

G3H Dataheets PDF



Part Number G3H
Manufacturers Omron
Logo Omron
Description Solid State Relays
Datasheet G3H DatasheetG3H Datasheet (PDF)

Solid State Relays G3@-VD G3H/G3HD New Models with International Standards Added to G3H Series (-VD in model number). Same Profile as LY1 and LY2 Bi-power Relays • Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”). • Socket type, same size as LY Power Relays. • Operation indicator provided to confirm input (models numbers with “N” before the suffix). Refer to Safety Precautions for All Solid State Relays. www.DataSheet4U.com CSM_G3H_G3HD_DS_E_3_1 Model Number Structure ■ .

  G3H   G3H



Document
Solid State Relays G3@-VD G3H/G3HD New Models with International Standards Added to G3H Series (-VD in model number). Same Profile as LY1 and LY2 Bi-power Relays • Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”). • Socket type, same size as LY Power Relays. • Operation indicator provided to confirm input (models numbers with “N” before the suffix). Refer to Safety Precautions for All Solid State Relays. www.DataSheet4U.com CSM_G3H_G3HD_DS_E_3_1 Model Number Structure ■ Model Number Legend G3H-@@@@@@-@ 1 1. 2. 2 3 4 5 6 7 8 6. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, and VDE standards Basic Model Name G3H: Solid State Relay Rated Load Power Supply Voltage 2: 200 VAC 03: 3A 7. 3, 4. Rated Load Current 5. Terminal Type S: Plug-in terminals 8. G3HD-@@@@-@ 1 1. 2. 3. 4. 2 3 4 5 6 7 5. 6. Terminal Type S: Plug-in terminals Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, VDE Basic Model Name G3H: Solid State Relay Load Power Supply Type D: DC Rated Load Power Supply Voltage X: 50 VDC Rated Load Current 03: 3A 7. 1 G3H/G3HD www.DataSheet4U.com Ordering Information ■ List of Models Isolation Photocoupler Phototriac coupler Yes No Zero cross function Yes Indicator Rated output load 3 A at 100 to 240 VAC (See note 1.) Rated input voltage 5 to 24 VDC 5 VDC 12 VDC 24 VDC Photocoupler Photocoupler Phototriac coupler --Yes No No 3 A at 4 to 48 VDC (See note 2.) 3 A at 100 to 240 VAC (See note 1.) 5 to 24 VDC 4 to 24 VDC 5 VDC 12 VDC 24 VDC Photocoupler Photodiode array Note: 1. 2. 3. 4. ----Yes 3 A at 4 to 48 VDC (See note 2.) 2.5 A at 24 to 240 VDC (See note 3.) 4 to 24 VDC 12 to 24 VDC G3HD-X03S-VD G3HD-202SN-VD G3HD-X03SN-VD G3H-203S-VD G3H-203SL-VD Model G3H-203SN-VD G3H-203SLN-VD Product is labelled “240 VAC”. Product is labelled “48 VDC”. Product is labelled “240 VDC”. When ordering, specify the rated input voltage. ■ Accessories (Order Separately) Connecting Sockets Item Connecting Mounting method/ Terminal type Hold-down clip PTF08A-E Front connecting Track mounted screw terminals PYC-A1 PT08 Back connecting Solder terminals PYC-P PCB terminals Wire-wrapping terminals PT08-0 PT08QN Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input Model G3H-203SN-VD Rated voltage 5 to 24 VDC 12 VDC 24 VDC G3HD-X03SN-VD 5 to 24 VDC G3H-203S-VD G3H-203SL-VD 4 to 24 VDC 5 VDC 12 VDC 24 VDC G3HD-X03S-VD 4 to 24 VDC G3HD-202SN-VD 12 to 24 VDC Operating voltage 4 to 28 VDC 4 to 6 VDC 9.6 to 14.4 VDC 19.2 to 28.8 VDC 4 to 28 VDC 3 to 28 VDC 4 to 6 VDC 9.6 to 14.4 VDC 19.2 to 28.8 VDC 3 to 28 VDC 9.6 to 28.8 VDC Impedance 15 mA max. (See note 2.) 390 Ω±20% 900 Ω±20% 2 kΩ±20% 15 mA max. (See note 2.) 390 Ω±20% 900 Ω±20% 2 kΩ±20% 25 mA max. (at 24 VDC) (See note 2.) 4 VDC max. 4 VDC max. 9.6 VDC max. 19.2 VDC max. 1 VDC min. 1 VDC min. 1 VDC min. 3 VDC max. 4 VDC max. 9.6 VDC max. 19.2 VDC max. 1 VDC min. 1 VDC min. 9.6 VDC max. Voltage level Must operate voltage G3H-203SLN-VD 5 VDC Must release voltage 1 VDC min. 1 VDC min. 1.5 kΩ +20%/–10% (See note 1.) 4 VDC max. 1.5 kΩ +20%/–10% (See note 1.) 3 VDC max. Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays. 2. With constant current input system. 2 G3H/G3HD www.DataSheet4U.com Output Model Rated load voltage G3H-203SN-VD G3H-203S-VD G3H-203SLN-VD G3H-203SL-VD G3HD-X03SN-VD G3HD-X03S-VD G3HD-202SN-VD 4 to 48 VDC 24 to 240 VDC 3 to 52.8 VDC 19.2 to 264 VDC 0.1 to 3 A at 40°C 0.001 to 2.5 A at 40°C 18 A (10 ms) 20 A (10 ms) 100 to 240 VAC 75 to 264 VAC Applicable load Load voltage range Load current 0.1 to 3 A at 40°C Inrush current 45 A 60 Hz, 1 cycle ■ Characteristics Model Operate time Release time G3H-203SN-VD/203S-VD G3H-203SLN-VD/203SL-VD G3HD-X03SN-VD/X03S-VD 1/2 cycle of load power source + 1 ms max. 1 ms max. 0.5 ms max. 2 ms max. G3HD-202SN-VD 5 ms max. 10 ms max. 3 V max. (output ON-resistance: 1.25 Ω max.) 5 mA max. (at 50 VDC) 0.1 mA max. (at 200 VDC) 1/2 cycle of load power source + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient humidity Certified standards EMC Weight 5 mA max. (at 100 VAC); 2.5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) 5 mA max. (at 200 VAC) 100 MΩ min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Destruction: 1,000 m/s2 Operating: –30°C to 80°C (with no icing) Storage: –30°C to 100°C (with no icing) 45% to 85% G3H: UL508, CSA C22.2 No. 14, EN60947-4-3 G3HD: UL508, CSA C22.2 No. 14, EN60950-1 Emission: EN55011 Group 1 Class B Immunity: .


E5ZN G3H G3HD


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)