DatasheetsPDF.com

E5ER-T Dataheets PDF



Part Number E5ER-T
Manufacturers Omron
Logo Omron
Description Programmable Temperature Controller
Datasheet E5ER-T DatasheetE5ER-T Datasheet (PDF)

Programmable Digital Controller E5ER-T A new 48 × 96-mm High-speed, Highprecision Digital Controller that is Programmable! • Create up to 32 programs with up to 256 segments total. • 0.01°C High resolution for Pt input. • High-speed sampling at 50 ms. • Settings easily made from a computer using the CX-Thermo. • RoHS compliance for world-wide application. Refer to Safety Precautions for All E5@R Models. www.DataSheet4U.com CSM_E5ER-T_DS_E_3_1 Model Number Structure ■ Model Number Legend E5ER.

  E5ER-T   E5ER-T



Document
Programmable Digital Controller E5ER-T A new 48 × 96-mm High-speed, Highprecision Digital Controller that is Programmable! • Create up to 32 programs with up to 256 segments total. • 0.01°C High resolution for Pt input. • High-speed sampling at 50 ms. • Settings easily made from a computer using the CX-Thermo. • RoHS compliance for world-wide application. Refer to Safety Precautions for All E5@R Models. www.DataSheet4U.com CSM_E5ER-T_DS_E_3_1 Model Number Structure ■ Model Number Legend E5ER-T@@@@@@@@-@@@ 1 2 3 4 5 6 7 8 9 1. Control method Blank:Standard or heating/cooling control P: Position proportional control 2. Output 1 R: NO relay output + NO relay output Q: Pulse output/current output + pulse output C: Current output + current output 3. Output 2 R: NO relay output + NO relay output Q: Pulse output/current output + pulse output C: Current output + current output 4. Auxiliary Outputs Blank:None 4: NO relay output + NO relay output T: 2 transistor outputs 5. Communications Blank: None 3: RS-485 communications 6. Optional Function Blank: None D: 4 event inputs 7. Input 1 B: Universal-input and 2 event inputs F: Universal-input and FB W: Universal-input and universal-input 8. Input 2 Blank: None W: Universal-input and universal-input 9. Other FLK: CompoWay/F communications (3 digits): (Modification type) Note: The above model number legend is intended as a functional description of models. Not all possible combinations of functions are available. Confirm model availability in Ordering Information when ordering. Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital Controller. E5AR/ER Digital Controller User's Manual (Cat. No. Z182) 1 E5ER-T www.DataSheet4U.com Ordering Information ■ Digital Controllers Programmable Digital Controllers Size Control type Control mode Outputs (control/ transfer) Optional functions Auxiliary outputs (SUB) Event inputs Serial communications None E5ER-TQ4B E5ER-TC4B RS-485 RS-485 E5ER-TQC43B-FLK E5ER-TQT3DW-FLK E5ER-TCT3DW-FLK None E5ER-TPRTDF Model 48 × 96 mm Basic control (1 loop) Standard control Heating and cooling control 2 (pulse + pulse/cur- 4 rent) 2 (current + current) 2 (pulse + pulse/current) 2 2 (pulse + pulse/cur- 2 4 2-loop control 2-loop standard control (See Note Single-loop heating and cooling control rent) Single-loop cascade control 2 (current + current) 2.) Single-loop control with remote SP Single-loop proportional control Control valve control (1 loop) Single-loop position-proportional control Relay outputs (1 open, 1 closed) Relay outputs (1 open, 1 closed) and 1 current 2 4 (See Note 2.) 4 None RS-485 E5ER-TPRQ43FFLK Note 1: Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC. 2: The outputs are transistor output. Inspection Results If an inspection report is required, it can be ordered at the same time as the Digital Controller using the following model number. Inspection Report (Order Separately) Model E5ER-K ■ Accessories (Order Separately) Terminal Cover Descriptions Terminal Cover for E5ER Model E53-COV15 Rubber Packing Model Y92S-P5 Note: The Rubber Packing is provided with the Digital Controller. 2 E5ER-T www.DataSheet4U.com Specifications ■ Ratings Supply voltage (See note 2.) Operating voltage range Power consumption Sensor input (See note 3.) CE Marking UL certification 100 to 240 VAC, 50/60 Hz 100 to 120 VAC, 50/60 Hz 85% to 110% of rated supply voltage 17 VA max. (with maximum load) 11 VA/7 W max. (with maximum load) Thermocouple: K, J, T, E, L, U, N, R, S, B, W Platinum resistance thermometer: Pt100 Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input) Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input) (Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input) 0 to 20 mA DC, 4 to 20 mA DC; load: 500 Ω max. (including transfer output) (Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC) Position-proportional control type (open, closed) N.O., 250 VAC, 1 A (including inrush current) Relay Output N.O., 250 VAC, 1 A (resistive load) Transistor Output Maximum load voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5 V max.; Leakage current: 0.4 mA max. 100 Ω to 2.5 kΩ Input ON: 1 kΩ max.; OFF: 100 kΩ min. Input ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max. Short-circuit: Approx. 4 mA Remote SP input Transfer output Control method Setting method Indication method Refer to the information on sensor input. Refer to the information on control output. 2-PID or ON/OFF control Digital setting using front panel keys or setting using serial communications 7-segment digital display and single-lighting indicator Character Height PV display: 9.5 mm; SV display: 7.2 mm; MV display: 7.2 mm Depends on model. −10 to 55°C (with no icing or condensation) For 3.


E5CN-H E5ER-T E5GN


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)