DatasheetsPDF.com

SUCS31215 Dataheets PDF



Part Number SUCS31215
Manufacturers Cosel
Logo Cosel
Description SUCS Type
Datasheet SUCS31215 DatasheetSUCS31215 Datasheet (PDF)

On-board type Ordering information SUCS1R5 R SUC 1 2 S 1R5 3 4 12 5 05 6 B *This product will be released in November 2004 including 3.3V output model. *Please see our HP for details when this product is released. 1 Series name 2 Single output 3 Output wattage 4 Input voltage 5 Output voltage 6 Mounting type B :SMD C :DIP MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT SUCS1R50505 1.5 VOLTAGE[V] *1 5 CURRENT[A] 0.3 SUCS1R50512 1.56 12 0.13 SUCS1R50515 1.5 15 0.1 SUCS1R51205 1.5 5 0.3 SU.

  SUCS31215   SUCS31215



Document
On-board type Ordering information SUCS1R5 R SUC 1 2 S 1R5 3 4 12 5 05 6 B *This product will be released in November 2004 including 3.3V output model. *Please see our HP for details when this product is released. 1 Series name 2 Single output 3 Output wattage 4 Input voltage 5 Output voltage 6 Mounting type B :SMD C :DIP MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT SUCS1R50505 1.5 VOLTAGE[V] *1 5 CURRENT[A] 0.3 SUCS1R50512 1.56 12 0.13 SUCS1R50515 1.5 15 0.1 SUCS1R51205 1.5 5 0.3 SUCS1R51212 1.56 12 0.13 SUCS1R51215 1.5 15 0.1 SUCS1R52405 1.5 5 0.3 SUCS1R52412 1.56 12 0.13 SUCS1R52415 1.5 15 0.1 SUCS1R54805 1.5 5 0.3 SUCS1R54812 1.56 12 0.13 SUCS1R54815 1.5 15 0.1 SPECIFICATIONS MODEL VOLTAGE[V] *2 CURRENT[A] INPUT *2 EFFICIENCY[%] VOLTAGE[V] CURRENT[A] www.DataSheet4U.com LINE REGULATION[mV] LOAD REGULATION[mV] -20 to +55C *3 RIPPLE[mVp-p] SU -40 to -20C *3 -20 to +55C *3 RIPPLE NOISE[mVp-p] OUTPUT -40 to -20C *3 -20 to +55C TEMPERATURE REGULATION[mV] -40 to +55C *4 DRIFT[mV] START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION ISOLATION INPUT-OUTPUT OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY CASE SIZE OTHERS COOLING METHOD PROTECTION CIRCUIT AND OTHERS SUCS1R50505 SUCS1R50512 SUCS1R50515 SUCS1R51205 SUCS1R51212 SUCS1R51215 SUCS1R52405 SUCS1R52412 DC4.5 - 9 DC9 - 18 DC18 - 36 0.417typ 0.433typ 0.417typ 0.169typ 0.176typ 0.169typ 0.084typ 0.087typ 72typ 72typ 72typ 74typ 74typ 74typ 74typ 75typ 5 12 15 5 12 15 5 12 0.3 0.13 0.1 0.3 0.13 0.1 0.3 0.13 20max 48max 60max 20max 48max 60max 20max 48max 40max 100max 120max 40max 100max 120max 40max 100max 80max 120max 120max 80max 120max 120max 80max 120max 120max 150max 150max 120max 150max 150max 120max 150max 120max 150max 150max 120max 150max 150max 120max 150max 200max 200max 200max 200max 200max 200max 200max 200max 50max 150max 180max 50max 150max 180max 50max 150max 80max 240max 290max 80max 240max 290max 80max 240max 20max 48max 60max 20max 48max 60max 20max 48max 20max (Minimum input, Io=100%) Fixed (TRM pin open) t5% adjustable by external VR SUCS1R52415 SUCS1R54805 SUCS1R54812 DC36 - 76 0.083typ 0.042typ 0.043typ 75typ 74typ 75typ 15 5 12 0.1 0.3 0.13 60max 20max 48max 120max 40max 100max 120max 80max 120max 150max 120max 150max 150max 120max 150max 200max 200max 200max 180max 50max 150max 290max 80max 240max 60max 20max 48max SUCS1R54815 0.042typ 75typ 15 0.1 60max 120max 120max 150max 150max 200max 180max 290max 60max 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 Works over 105% of rating and recovers automatically AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C) -40 to +71C, 20 - 95%RH (Non condensing) (Required Derating), 3,000m (10,000feet) max -40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis 490.3m/s2 (50G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL, EN60950-1 22.4X7.0X13.2mm (WXHXD) Convection *1 *2 *3 *4 * SUCW1R5xx12/SUCW1R5xx15 is available as single output, +24V/+30V. Rated input 5V, 12V, 24V or 48V DC Io=100% Ripple and Ripple Noise is measured by using measuring board with capacitor with in 25mm from output terminal. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. Parallel operation with other model is not possible. G-20 On-board type Ordering information SUCS3 R SUC S 1 2 3 3 4 12 5 05 6 B 7 -O *This product will be released in February 2005 including 3.3V output model. *Please see our HP for details when this product is released. 1 Series name 2 Single output 3 Output wattage 4 Input voltage 5 Output voltage 6 Mounting type B :SMD C :DIP 7 Optional G :Capacitor between Input and Output is removed. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT SUCS30505 3 VOLTAGE[V] *1 5 CURRENT[A] 0.6 SUCS30512 3 12 0.25 SUCS30515 3 15 0.2 SUCS31205 3 5 0.6 SUCS31212 3 12 0.25 SUCS31215 3 15 0.2 SUCS32405 3 5 0.6 SUCS32412 3 12 0.25 SUCS32415 3 15 0.2 SUCS34805 3 5 0.6 SUCS34812 3 12 0.25 SUCS34815 3 15 0.2 SPECIFICATIONS MODEL VOLTAGE[V] *2 INPUT CURRENT[A] *2 EFFICIENCY[%] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] www.DataSheet4U.com LOAD REGULATION[mV] -20 to +55C *3 RIPPLE[mVp-p] -40 to -20C *3 SU -20 to +55C *3 RIPPLE NOISE[mVp-p] OUTPUT -40 to -20C *3 -20 to +55C TEMPERATURE REGULATION[mV] -40 to +55C *4 DRIFT[mV] START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] PROTECTION OVERCURRENT PROTECTION CIRCUIT AND REMOTE ON/OFF OTHERS ISOLATION INPUT-OUTPUT OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY CASE SIZE OTHERS COOLING METHOD *1 *2 *3 *4 * SUCS30505 SUCS30512 SUCS30515 SUCS31205 SUCS31212 SUCS3.


SUCS31212 SUCS31215 SUCS32405


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)