DatasheetsPDF.com

TQN25A48S12J Dataheets PDF



Part Number TQN25A48S12J
Manufacturers Emerson
Logo Emerson
Description DC-DC / Intermediate Bus Converter
Datasheet TQN25A48S12J DatasheetTQN25A48S12J Datasheet (PDF)

Embedded Power for Business-Critical Continuity Quarter-Brick Series Narrow Input IBC Total Power: 240 -300W Input Voltage: 48VDC # of Outputs: Single Rev.04.02.08 Quarter-brick narrow input IBC 1 of 4 Special Features • 48 V input with isolated 12 V output • Efficiencies up to 96% • Open loop regulation • Fully rated 240 W @ 70 °C, 200 LFM • Overcurrent protection • Operates with no load • Auto restart after fault condition • Remote ON/OFF • Parallelable • Over-temperature protection • Avail.

  TQN25A48S12J   TQN25A48S12J


Document
Embedded Power for Business-Critical Continuity Quarter-Brick Series Narrow Input IBC Total Power: 240 -300W Input Voltage: 48VDC # of Outputs: Single Rev.04.02.08 Quarter-brick narrow input IBC 1 of 4 Special Features • 48 V input with isolated 12 V output • Efficiencies up to 96% • Open loop regulation • Fully rated 240 W @ 70 °C, 200 LFM • Overcurrent protection • Operates with no load • Auto restart after fault condition • Remote ON/OFF • Parallelable • Over-temperature protection • Available RoHS compliant • 2 Year Warranty This series is a new, high efficiency, Quarter-Brick, isolated, Intermediate Bus Converter series that provides up to 300 Watts of output power. The series is designed to convert 48 Volts ±10% to a loosely regulated 12 Volts at full rated load up to 25 A and efficiencies up to 96%. This converter is available in four package types, standard quarter-brick through-hole, through-hole vertical, standard quarter-brick surface-mount, and quarter-brick surface-mount solder ball. In addition, this series features remote ON/OFF, no-load operation, input undervoltage protection as well as output overvoltage and overcurrent protection. Safety UL/cUL : CAN/CSA 22.2 No. 60950 UL 60950 File No. E139421 TÜV Product Service (EN60950) Certificate No. B03 04 19870213 Embedded Power for Business-Critical Continuity Specifications All specifications are typical at nominal input, full load at 25 °C ambient unless otherwise stated. Rev.04.02.08 Quarter-brick narrow input IBC 2 of 4 OUTPUT SPECIFICATIONS Output voltage Current share accuracy Line regulation Load regulation Minimum load Overshoot Undershoot Ripple and noise (See Note 1) Transient response (See Note 2) Overvoltage setpoint INPUT SPECIFICATIONS Input voltage range Input current Input reflected ripple Remote ON/OFF Under-voltage lockout Start-up time (See Note 4) Nominal 48 Vdc No load Remote OFF (See Note 3) ON OFF Power up Power down Power up Power down ±10% Vdc 100 mA typ. 2 mA typ. 34 mA rms 100 mA pk-pk >1.7 Vdc <0.8 Vdc 41.0 V 38.6 V <50 ms <20 ms 5-20 MHz Deviation Full load Low line to high line Full load to min. load 12 V 10% ±10% max. 6% max. 0A 3.0% max. 200 mV max. 150 mV pk-pk <100 mV <100 μs recovery to within total error band 13.8 V EMC CHARACTERISTICS Conducted emissions Immunity: ESD air ESD contact Radiated field enclosure Conducted (dc power) Conducted (signal) GENERAL SPECIFICATIONS Efficiency Isolation Switching frequency Approvals and standards (See Note 6) Material flammability Weight MTBF Representative model: Half load Input/output Fixed Up to 96% typ. 2250 Vdc 300 kHz typ. EN60950 (TÜV Product Service) UL/cUL60950 UL94V-0 56.66 g (2 oz) MIL-HDBK-217F 1,000,000 hours 25 A @ 48 Vin, 40 °C ambient 100% load ground benign Telcordia SR-332 2,828,160 hours EN55022 (See Note 5) EN55022 (See Note 5) EN61000-4-2 4 kV EN61000-4-2 4 kV EN61000-4-3 3 V/m EN61000-4-6 3 V EN61000-4-6 3 V Level A Level B ENVIRONMENTAL SPECIFICATIONS Thermal performance (300 LFM airflow) Operating ambient, temperature Non-operating 0 °C to +80 °C -55 °C to +125 °C Embedded Power for Business-Critical Continuity Specifications Contd. Rev.04.02.08 Quarter-brick narrow input IBC 3 of 4 RATED OUTPUT POWER 240 W 300 W INPUT VOLTAGE 43.2-52.8 Vdc 43.2-52.8 Vdc OUTPUT VOLTAGE 12 V 12 V INPUT CURRENT (MAX) 6A 7A OUTPUT CURRENT (MAX.) 20 A 25 A OVER CURRENT SETPOINT 25 A 29 A EFFICIENCY HALF/FULL LOAD 96%/95% (typ.) 96%/95% (typ.) MODEL NUMBER (9,10) TQN20A48S12J TQN25A48S12J Part Number System with Options TQN25A48S12SB-RJ RoHS Compliance (9) J = Pb-free (RoHS 6/6 compliant) Remote ON/OFF Logic No Suffix = Positive Suffix ‘R’ = Negative Mounting Options No Suffix = Through Hole Horizontal V = Through Hole Vertical (8) S = Surface Mount Standard (8) SB = Surface Mount Solder Ball (8) Nominal Output Voltage 12 = 12 Volts Number of Outputs S = Single Output Nominal Input Voltage 48 = 48 Volts Product Family T = Intermediate Bus Converter Package Q - Standard Quarter-Brick Type of Input Voltage Range N = Narrow (±10%) Output Current 20A = 20 Amps 25A = 25 Amps Notes 1 2 Measured as per recommended set-up. See Application Note 140 for details. di/dt = 10 A/μs, Vin = 48 Vdc, Tc = 25 °C, load change = 50% lo max. to 75% lo max. and 75% lo max. to 50% lo max. 3 Measured with external filter. See Application Note 140 for details. 4 Start-up into resistive load. 5 The Quarter-Brick Narrow Input series of converters meet levels A and B conducted emissions with external components. See Application Note 140 for details. 6 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 7 Use of additional high quality ceramic output capacitors is recommended in the end system. 8 Consult factory for availability.9 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 10 NOTICE: Some model.


TQN25A48S12-VJ TQN25A48S12J TQN25A48S12SB-RJ


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)