DatasheetsPDF.com

SIL40C2-00SADJ-VJ Dataheets PDF



Part Number SIL40C2-00SADJ-VJ
Manufacturers Emerson
Logo Emerson
Description DC/DC Converter
Datasheet SIL40C2-00SADJ-VJ DatasheetSIL40C2-00SADJ-VJ Datasheet (PDF)

Embedded Power for Business-Critical Continuity SXX06E Rev. 08.01.06 Page 1 of 2 SIL40C2 Series 4.5-13.8 Vin Single C-Class Non-Isolated 40 A Current Rating Input Voltage: 4.5-13.8 V No. of Outputs: Single Rev. 07.02.08 SIL40C2 1 of 5 Electrical Specifications Special Features • 40 A current rating • Input voltage range: 4.5-13.8 V • Output voltage: 0.6-5 V • Industry leading value • Cost optimized design • Excellent transient response • Output enable • Output voltage adjustability.

  SIL40C2-00SADJ-VJ   SIL40C2-00SADJ-VJ


Document
Embedded Power for Business-Critical Continuity SXX06E Rev. 08.01.06 Page 1 of 2 SIL40C2 Series 4.5-13.8 Vin Single C-Class Non-Isolated 40 A Current Rating Input Voltage: 4.5-13.8 V No. of Outputs: Single Rev. 07.02.08 SIL40C2 1 of 5 Electrical Specifications Special Features • 40 A current rating • Input voltage range: 4.5-13.8 V • Output voltage: 0.6-5 V • Industry leading value • Cost optimized design • Excellent transient response • Output enable • Output voltage adjustability • Pathway for future upgrades • Supports silicon voltage migration • Resulting in reduced design-in and qual time • RoHS Compliant Output Output voltage Output setpoint accuracy Line regulation Load regulation Min./max. load Overshoot Undershoot Ripple and noise 5 Hz to 20 MHz Transient response At turn-on At turn-off See Note 1 See Notes 1, 2 See Note 5 0.1% trim resistors Low line to high line Full load to min. load 0.6-5 V ±1.0% ±0.2% ±0.5% 0 A/40 A 0.5% max. 100 mV max. 25 mV Vin=5 V, Vout=2.5 V 130 mV max. deviation 50 µs recovery to within regulation band 4.5-13.8 Vdc Minimum load Remote OFF See Note 3 Remote ON/OFF 50 mA 5 mA 25 A @ lo max. 3 ms Input Input voltage range Input current Input current (max.) Start-up time Safety UL, cUL CAN/CSA 22.2 No. E139421 UL6950 File No. TBD TÜV Product Service (EN60950) Certificate No. TBD CB report and certificate to IEC60950 Embedded Power for Business-Critical Continuity General Efficiency Switching frequency Approvals and standards (pending) Material flammability Weight MTBF 12 V @ 40 °C, 100% load Bellcore 332 Vin=5 V, Vo=2.5 V, lo=20 A Fixed 94% 500 kHz EN60950 UL/cUL6950 UL94V-0 17 g (0.06 oz.) 6,749,409 hours Rev. 07.02.08 SIL40C2 2 of 5 Coplanarity 150 µm Environmental Specifications Thermal performance See Note 5 Operating ambient, temperature Non-operating 0 °C to +70 °C -40 °C to +125 °C Hiccup, non-latching Hiccup, non-latching See Note 6 See Note 7 0 µF 0 µF Protection Short-circuit Overvoltage protection Recommended System Capacitance Input capacitance Output capacitance Ordering Information Output Power (Max.) 200 W 200 W 200 W Input Voltage 4.5-13.8 Vdc 4.5-13.8 Vdc 4.5-13.8 Vdc OVP N/A N/A N/A Output Voltage 0.6-5 Vdc 0.6-5 Vdc 0.6-5 Vdc Output Current (Min.) 0A 0A 0A Output Current (Max.) 40 A 40 A 40 A Efficiency (Typical) 94% 94% 94% Regulation Line Load ±0.2% ±0.2% ±0.2% ±0.5% ±0.5% ±0.5% Model Number (3,5) SIL40C2-00SADJ-VJ SIL40C2-00SADJ-HJ SMT40C2-00SADJJ Embedded Power for Business-Critical Continuity Part Number System with Options Product Family Rated Output Current Performance Generation Input Voltage Output Voltage Mounting Option Rev. 07.02.08 SIL40C2 3 of 5 RoHS Compliance(8) SIL Product Family SIL = Single In Line SMT = Surface Mount 40 Rated Output Current 06 = 6 A 15 = 15 A 20 = 20 A 30 = 30 A 40 = 40 A C Performance C = Cost Optimized 2 Generation Blank = Standard Part 2 = Increased Current Density - 00 Input Voltage 00 = 4.5-13.8 V SADJ Output Voltage Single Adjustable Output - V Mounting Option V = Vertical H = Horizontal J RoHS Compliance J = Pb-free RoHS 6/6 Compliant Output Voltage Adjustment of the SIL40C2 Series The ultra-wide output voltage trim range offers major advantages to users who select the SIL40C2 series. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 0.6-5 V. When the SIL40C2 converter leaves the factory, the output has been adjusted to the default voltage of 0.6 V. Standard Application Drawing Power Good Notes: 1 Measured as per recommended system capacitance. 2 di/dt = 10 A/µs, Vin = Nom, Tc = 25 °C, load change = 0.75 lo to full lo and full lo to 0.75. 3 External input fusing is recommended. 4 Additional part numbers may be available with different output voltages. 5 Airflow dependent, 100 LFM minimum required. 6 No capacitors needed for ripple current capability. 7 No capacitors needed for stability. 8 TSE RoHS 5/6 (non-Pb-free) compliant versions are also available on special request, please contact our local sales representative for details. 9 NOTICE: Some models may not support all options. Please contact your local representative or use the on-line model number search tool at http://www. powerconversion.com to find a suitable alternative. 10 To order a Horizontal Mounting option with a pin length of 0.165", please use the model # SIL40C2-00SA-HP5J Enable 6 5 SIL40C2 1,2,3 9 V out +R sense V in 10,11 7,8 C in R trim (for trim down) C out 4 R L O A D GND Figure 1: Standard Application Drawing Embedded Power for Business-Critical Continuity Rev. 07.02.08 SIL40C2 4 of 5 Mechanical Drawings Dimensions in inches (mm). Tolerances (unless otherwise specified) 2 Places ±0.030 (±0.76) 3 Places ±0.010 (±0.25) Vertical Mount 1.200 (30.48) 0.427 (10.85) 1.100 (27.94) 0.050 (1.27) REF PIN 1 0.100 (2.54) 0.100 (2.54) TYP 9 PLACES 1..


SIL40C2-00SADJ-HJ SIL40C2-00SADJ-VJ SIP20C-05S1V5J


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)