AC-DC / 10W - 85W

Embedded Power for Business-Critical Continuity LPS40 Series 40 Watts Total Power: Input Voltage: # of Outputs: ...


Emerson

LPS41

File Download Download LPS41 Datasheet


Description
Embedded Power for Business-Critical Continuity LPS40 Series 40 Watts Total Power: Input Voltage: # of Outputs: 40 - 55 Watts 85 - 264 VAC 120 - 300 VDC Single Rev. 7.8.09_4 LPS40 Series  of 3 Special Features Universal input 3” x 5” footprint Less than 1U high Remote sense Terminal block option (-T) Built-in EMI filter Low output ripple Adjustable output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Electrical Specifications Input Input ra­nge: Frequency: Inrush current: Input current: Efficiency: EMI filter: Safety ground leakage current: 85 - 264 VAC; 120 - 300 VDC 47 - 440 Hz < 18 A peak @ 115 VAC; < 36 A peak @ 230 VAC, cold start @ 25 °C 1 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 class B conducted < 0.5 mA @ 50/60 Hz, 264 VAC input Output Maximum power: Adjustment range: Hold-up time: Overload protection: 40 W for convection; 55 W with 30CFM forced air -5, +10% minimum 20 ms @ 40 W load, 115 VAC nominal line Short circuit protection on all outputs Case overload protected @ 110 -145% above peak rating Safety UL UL60950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P94100375 (74-sec)203 CB Certificate and report 1119, 1125, 1126, 1127 CE Mark (LVD) Overvoltage protection: 5 V output; 5.7 to...