DC-DC / Intermediate Bus Converter
60Amps
Total Power: Input Voltages: No. of Outputs:
200 Watts (3.3V @ 60A) 48 V Single
AEH60 ALH60 (Open Frame)
Ultra...
Description
60Amps
Total Power: Input Voltages: No. of Outputs:
200 Watts (3.3V @ 60A) 48 V Single
AEH60 ALH60 (Open Frame)
Ultra High Efficiency Half Brick
Input
Input range Input Surge Efficiency
Electrical Specs
36-75 VDC 100V / 100ms 91% @ 3.3V (Typical)
Control
Enable TTL compatible (positive or negative enable logic control options)
Output
Regulation (Line, Load, Temp) Ripple and Noise1 Remote Sense <2% 2% typical (100mVp-p max) Up to 10%Vout ±10% of nominal output 60mV typical output deviation 25% step change 150 µS recovery time 135% nominal output (latching) 115% of full load (latching) Shutdown - autorecovery mode 1500 Vdc
Special Features
High efficiency, 3.3V@ 91% (Typical) Baseplate (AEH) or Open frame (ALH) design Low output ripple and noise High capacitive load limit on start-up Remote sense compensation Regulation to zero load Fixed frequency switching Industry Std features: Input UVLO, OCP, OVP, OTP; Short ckt protection; ±10% Output Adjust Positive or Negative enable logic control option Meets Basic Insulation
Output Voltage Adjust Range Transient Response
Overv Voltage Protection Over Current Protection Over Temperature Protection Isolation Voltage
Environmental
Operating temperature -40°C to +100°C Baseplate (AEH60) -40°C to +85°C Ambient (ALH60) Storage temperature: -55°C to +125°C Overtemperature protection: 115°C PCB Temperature (Typical) MTBF: >1 million hours
Safety
UL, cUL 60950 Recognized TUV EN60950 Licensed
2
North America (US...