Embedded Power for Business-Critical Continuity
AIF12W300
600 Watts
Total Power: 600 Watts (48 [email protected] Amps) Input Volta...
Embedded Power for Business-Critical Continuity
AIF12W300
600 Watts
Total Power: 600 Watts (48
[email protected] Amps) Input Voltage: 300 V # of Outputs: Single
Rev. 06.11.08 AIF12W300 1 of 2
Electrical Specifications
Input
Special Features
600 W continuous power at 100 °C baseplate temperature 108 W/in3 (6.6W/cm3) High efficiency - up to 90% Low output ripple and noise Positive and Negative enable function Excellent transient response OVP, OCP, V Adj control with ALPTM Paralleable with accurate current sharing
Input range: Input surge: Efficiency:
250 - 420 Vdc 500 V / 100 ms 90% typical 400 mV typical down to no load 200 mV typical 480 mV typical 5% max deviation with 25% to 75% full load, slew = 1 A / uS 3% typical, 5% max (≥80% of Io max) 125% ± 5% Vo (nominal) - latch up 105% - 120% Io maximum - hiccup 150% maximum - hiccup 80 to 120% Vo linear programming (see page 2 graph) TTL compatible (positive & negative enable options) 20 to 100% Io linear programming 3.3 to 5.5 Vp-p @ 800 KHz ±10% 4.5 Vp-p typical@ 800 KHz ±5% High (Vo) = power good 10 mV/°K (2.73 = 0 °C) 0 to 1 mA (1 mA = 100% Io rated) ± 0.1 mA 120 to 150% Vo 12 V ± 1.5 V, 10 mA
Output
Load regulation: Line regulation: Noise / ripple: Transient response: Current share accuracy: Overvoltage protection: Current limit: Short-circuit protection:
Control
Voltage Adjust*: Enable: Current limit ddjust: Clock input (external sync): Clock output (internal clock): Power good identification: Temperature monit...