Filter specification
Tfs119.doc
version 1.4 28.06.2000 _____________________________________________________________________________________...
Description
Tfs119.doc
version 1.4 28.06.2000 ______________________________________________________________________________________________________
VI TELEFILTER Filter Specification TFS 119 1/5 ______________________________________________________________________________________________________
Measurement condition
Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedances for input: 1 kOhm // -1,5 pF for output: 1 kOhm // -1,5 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 119 is the insertion loss. The insertion loss ae is defined as the insertion loss at the nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 119.6 MHz without tolerance. The specified values have to be reached in operating temperature range.
Data
Insertion loss (Reference level) Nominal frequency Centre frequency 1 dB bandwidth
fN fC
typ. Value
ae 2,45 dB
tolerance/limit
1,95 ... 3,95
119,605 MHz BW 61 59 58...72 70...90 1,2 : 1 GD 10,8 µs max. max. kHz dB dB dB min. min. min. min.
119,600 MHz 20 30 10 1,8 : 1 16,5 5 µs dBm dB dB dB
Relative attenuation arel fN ± 0.8 MHz ... fN ± 1,8 MHz MHz fN ± 1,8 MHz ... fN ± 6 fN ± 6 MHz ... fN ± 100 MHz VSWR @ fN Group delay @ fN Input power Operating temperature range Temperature coefficient of frequency Frequency inversion temperature www.Data...