Filter specification
Tfs111.doc
Version 1.2
05.01.02
VI TELEFILTER
Filter Specification
TFS 111 - 1/4
1. Measurement condition Ambient ...
Description
Tfs111.doc
Version 1.2
05.01.02
VI TELEFILTER
Filter Specification
TFS 111 - 1/4
1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 °C 0 dBm. for input: for output:
890 Ω - 5,6 pF . 680 Ω - 5,9 pF .
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 111 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range.
Data Insertion loss (Reference level) Centre frequency ae
typ. value 11,9 111 dB MHz
tolerance / limit max. 14 111,0 ± 0,06 dB MHz
fc at ambient temperature TA (fCAT)
Pass band at ambient temperature TA: Relative attenuation fC - 425 fC - 800 fC + 475 fC - 1395 fC + 1200 fC - 1535 fC + 1375 fC - 10 fC + 1500 kHz ..... kHz ..... kHz ..... kHz ..... kHz ..... kHz ..... kHz ..... MHz ..... kHz ..... arel fC + 475 fC - 425 fC + 800 fC - 1210 fC + 1375 fC - 1395 fC + 1500 fC - 1535 fC + 10 kHz kHz kHz kHz kHz kHz kHz kHz MHz 60...45 45...55 1,13 160 3° 10° C + 1,7 - 0,06
fC - 0,425 MHz........fC + 0,475 MHz
max. 3 max. 10 max. 10 min. 20 min. 20 min. 30 min. 30 dB dB µs ns ...