DatasheetsPDF.com

GC70xxF Dataheets PDF



Part Number GC70xxF
Manufacturers Green Power Solutions
Logo Green Power Solutions
Description BAR CLAMP
Datasheet GC70xxF DatasheetGC70xxF Datasheet (PDF)

Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: [email protected] GC70…F BAR CLAMP FOR HOCKEY PUK DEVICES www.datasheet4u.com Clamping total thikness of assembly from 44mm to 135mm Pre-loaded to the specific clamping force (5 ÷ 12 kN) Maximum device diameter: 57mm Surface passivation to provide extra protection Hexagon head bolt partially threaded M8x1.25, UNI5737, 8.8 steel Various lengths of b.

  GC70xxF   GC70xxF


Document
Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: [email protected] GC70…F BAR CLAMP FOR HOCKEY PUK DEVICES www.datasheet4u.com Clamping total thikness of assembly from 44mm to 135mm Pre-loaded to the specific clamping force (5 ÷ 12 kN) Maximum device diameter: 57mm Surface passivation to provide extra protection Hexagon head bolt partially threaded M8x1.25, UNI5737, 8.8 steel Various lengths of bolts and insulators Flat clamping head for optimal clamping force application Four styles available User friendly clamping force indicator UL94 certified insulation material Parameter Unit g Types 'GC70S…F GC70B…F GC70…05F GC70…08F GC70…10F GC70…12F Testing conditions Notes Min 340 430 Values Typ Max 460 570 05 08 10 12 ± 10% Weight Clamping Force* kN Clamping Force tolerance Insulation Voltage VRMS 1 min Noryl  ∗∗ E121562 °C mm mm °C mm UL94 V-1 Flame class rating UL94 V-0 Flame class rating CSA Flammability mm mm * Other clamping forces available: contact factory  ** Noryl is a registered trade mark of General Electric 3000 Insulating Material UL File Max. working temperature Creepage distance: Clearance distance: Storage temperature -30 28 20.3 -40 1.5 8.00 1.00 110 110 Flammability Document GC70…FT001 BAR CLAMP FOR HOCKEY PUK DEVICES GC70…F ORDERING INFORMATION TABLE Clamps can be ordered using the following part numbering system GC70 B (1) N (2) B (3) A (4) 10 (5) F S (6) (1) Construction type: www.datasheet4u.com B = with double bar S = with single bar N = upper side R = lower side see table below see table below 05 08 10 12 (2) Insulator position: (3) Insulator code: (4) Bolt code: (5) Clamping force (in kN): K (6) Special accessories blank = no accessories S = extra bar spacer K: Total thickness of the assembly to be clamped For thicknesses S' Min < K < S Min an additional 4mm thick bar spacer is needed (see list of special accessories) Type GC70BN…F: suggested insulator/bolt types Allowed clearance S S' Min [mm]** 44 54 64 74 84 94 104 S Min [mm] 48 58 68 78 88 98 108 S Max [mm] 63 73 83 93 103 113 123 (3) A B B C C C D Insulator choice Ins. Length [mm] 50 70 70 95 95 95 120 (4) Z A B C D E F Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160 Max height T [mm] 110 120 130 140 150 160 170 ** with additional bar spacer only Type GC70BR…F: suggested insulator/bolt types Allowed clearance S Insulator choice S' Min [mm]** 44 54 64 74 84 94 104 S Min [mm] 48 58 68 78 88 98 108 S Max [mm] 63 73 83 93 103 113 123 (3) A A B B C C C Ins. Length [mm] 50 50 70 70 95 95 95 (4) Z A B C D E F Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160 K Max height T [mm] 123 133 143 153 163 173 183 ** with additional bar spacer only Type GC70SN…F: suggested insulator/bolt types Allowed clearance S Insulator choice S' Min [mm]** 44 54 64 74 84 94 104 S Min [mm] 48 58 68 78 88 98 108 S Max [mm] 63 73 83 93 103 113 123 (3) A B B C C C D Ins. Length [mm] 50 70 70 95 95 95 120 (4) Z A B C D E F Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160 Max height T [mm] 110 120 130 140 150 160 170 ** with additional bar spacer only Type GC70SR…F: suggested insulator/bolt types Allowed clearance S Insulator choice S' Min [mm]** 56 66 76 86 96 106 116 # S Min [mm] 60 70 80 90 100 110 120 S Max [mm] 75 85 95 105 115 125 135 (3) B B B C C D D Ins. Length [mm] 70 70 70 95 95 120 120 (4) Z A B C D E F Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160 Max height T [mm] 123 133 143 153 163 173 183 ** with additional bar spacer only 4 3 BAR CLAMP FOR HOCKEY PUK DEVICES GC70…F BAR CLAMP OUTLINES 95 95 12 50 up to 120 12 12 Ø12 58 T 12 50 up to 120 S 58 12 70 14 70 25 GC70BN...F 95 GC70BR...F 95 14 12 50 up to 120 12 12 12 25 T 50 up to 120 Ø12 58 29 14 70 Ø12 S 70 25 22 Min. GC70SN...F GC70SR...F Dimensions in mm - Tolerances according to ISO 2768 MK # 25 S 58 T S T Ø12 39 www.datasheet4u.com 14 BAR CLAMP FOR HOCKEY PUK DEVICES GC70…F www.datasheet4u.com PRESSURE DISC S Min SPECIAL ACCESSORIES The following special accessories are available on request (see ordering information table) Bar spacer 95 S Max OPTIONAL BAR SPACER S' Min Ø13 Dimensions in mm - Tolerances according to ISO 2768 MK In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without notice. # 4 25 .


AN9515 GC70xxF TMXA84622


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)