Front End ( Antenna) Crystal Filter
Specification Filter type :
www.datasheet4u.com
Issue: 01 QF3100 Front End ( Antenna) Crystal Filter min.
135 ±4 1 8 ±1...
Description
Specification Filter type :
www.datasheet4u.com
Issue: 01 QF3100 Front End ( Antenna) Crystal Filter min.
135 ±4 1 8 ±15 ±35
Date: 2003-03-10
Parameter
Frequency range Standard frequencies Pass bandwidth Pass band ripple Insertion / transducer attenuation Shape factor SF Selectivity
typ.
max. Unit
180 MHz kHz kHz dB dB kHz kHz kHz dB dB Ω // pF Ω // pF µs mW mW °C °C °C mm female gram V
Condition
@ 3 dB @ fo ± 2 kHz … dB / … dB @ 20 dB @ 45 dB @ … dB
Spurious response attenuation Ultimate attenuation Termination Input Output Group delay Input Power nominal Maximum (for 10 sec) Operating temperature range Operable temperature range Storage temperature range Enclosure (see drawing) Terminals Weight Packing ESD Sensitivity
25 60 50 // 0 50 // 0
0,1 1 0 +60 -20 +70 -40 +85 61 x 26,2 x 26,2 BNC, N or SMA bulk 1500
Option I HBM as in IEC 61000-42
Notes: 1. Terminology and test conditions are according to IEC standard IEC60368-1, unless otherwise stated
Ordering Code:
Model (Specification) QF3100 Option I Frequency [MHz] BNC 144,250
Products Buchfinkenweg 8 DE-74931 Lobbach Germany page 1(2)
wwwAXTAL.com phone: +49 (6226) 9719689 fax: +49 (6226) 970133 E-mail: info@axtal.com
Enclosure drawing
www.datasheet4u.com
Pin connections
Terminal Symbol Function 1* IN Input 2* OUT Output screw GND Ground, Case * marking on request only
Environmental conditions
Test Visual inspection, dimensions Sealing tests Solderability Resistance to soldering heat Shock Bump Free fall Vibr...
Similar Datasheet