DatasheetsPDF.com

U1602 Dataheets PDF



Part Number U1602
Manufacturers ECS
Logo ECS
Description (U1602 / U1603) Energy Control System
Datasheet U1602 DatasheetU1602 Datasheet (PDF)

www.datasheet4u.com U1602, U1603 ENERGY • CONTROL • SYSTEM 3-349-046-03 2/8.05 • 64 processing channels physical inputs or LON meter outputs can be assigned for the calculation of energy, power and costs Energy Control Language for the programming of analysis, monitoring and optimization applications LON interface for 63 LON devices Two RS 232 interfaces (115 kBit/s) for connection to PC, modem, printer or radio-controlled clock Two ECS LAN interfaces for the linking of individual summators o.

  U1602   U1602


Document
www.datasheet4u.com U1602, U1603 ENERGY • CONTROL • SYSTEM 3-349-046-03 2/8.05 • 64 processing channels physical inputs or LON meter outputs can be assigned for the calculation of energy, power and costs Energy Control Language for the programming of analysis, monitoring and optimization applications LON interface for 63 LON devices Two RS 232 interfaces (115 kBit/s) for connection to PC, modem, printer or radio-controlled clock Two ECS LAN interfaces for the linking of individual summators over great distances Simple software update via serial interface (Flash) QUALITY MANAGEMENT SYSTEM • • • • • U1603 • 6 universal inputs: ± 5 mA, ± 20 mA, ± 10 V, S0 pulse • • 2 analog outputs: ± 20 mA or ± 10 V 2 relays and 4 MOS switches for controlling external processes DQS certified per DIN EN ISO 9001 Reg. No.1262 Applications The U1602 micro-summator and the U1603 mini-summator are used as PC adapters or LON interfaces for the ECS LAN, and are not equipped with any display or operating elements. Inputs and outputs expand the U1603 mini-summator into a miniature data collector and optimization unit. Meter Inputs Up to 63 LON devices can be connected to the U1602 microsummator or the U1603 mini-summator via the easy-to-wire, polarity-reversal-protected, electrically isolated LON interface: • Multifunctional power meter A2000 • Programmable multi-measuring transducer DME 400 • Electricity meter U1681, U1687, U1689 • Meter reading module U1660 • Analog input module U1661 • Relay output module OCL210 by Littwin Analysis All relevant energy and consumption data are logged over defined time periods at a programmable interval via 64 processing channels and are stored to memory as load profiles along with the corresponding maximum values. Beyond this, the U1603 mini-summator is also capable of processing analog or pulse signals via six input channels with configurable parameters. Operation The U1603 is equipped with two analog outputs, four MOS switches and two relays (changeover contacts) for the control of external processes. Data exchange with a PC, as well as remote querying via modem are accomplished via the RS 232 interface (115 kBit / s). A radio-controlled clock for the synchronization of system time, as well as a report printer, can also be connected. Networking Individual summators can be linked into a network over great distances with the multi-master compatible ECS LAN with free selection of network topology, and have unrestricted access to all data available from each of the network users. Universal Application Both the U1602 micro-summator and the U1603 mini-summator are suitable for customer-specific calculations, analyses, monitoring and optimization thanks to integrated high-level intelligence and the system-specific ECL programming language - even independent of the Energy Control System. Variable Installation The compact housing and IP protection have been laid out for rugged industrial use, and the modules can be mounted to tophat rails in accordance with EN50022. They can also be mounted with screws, or integrated into the control cabinet. Installation is user-friendly and easy with plug-in screw terminals. GOSSEN METRAWATT GMBH U1602, U1603 ENERGY • CONTROL • SYSTEM Applicable Regulations and Standards EN 61010-1 www.datasheet4u.com DIN 43864 VDE 0470 Part 1 IEC 68 Part 2-6 UL 94 EMC Standards Safety requirements for electrical equipment for measurement, control and laboratory use Current interface for pulse transmission between impulse meters and tariff devices IP protection provided by enclosures (DIN 40050) Basic environmental test procedure Sinusoidal oscillation Test for flammability of plastic materials for parts in devices and appliances see Technical Data Power Instantaneous Power P mom Determined from the time interval between the last two pulses (with connection to E1 ... E12) For all stored measuring intervals (measurement data list) The 10 highest values from all measuring intervals as of a defined starting time Maximum value for the current day, and for each of the last 10 days Maximum daily value for the current month, and for each of the last 12 months Maximum value for the current year, and for each of the last 4 years Mean Values for Measuring Intervals P int P maxInt P maxDay P maxMonth P maxYear Maximum Values for Measuring Intervals, with Date and Time Stamp Symbols and their Meanings Symbol X X2 Y Y2 Meaning Measured quantity, analog input Upper range value of measured quantity Output quantity, analog output Upper range value of output quantity Technical Data Inputs (U1603) The 6 inputs can be configured individually with the DIP switches. Analog Input (Current) Memory Capacities per Channel Energy Cumulative Energy as of a Defined Starting Time E tot E tot T1 E tot T2 E tot T1T2 E Day E Month E Year E Int E maxInt E maxDay E maxMonth E maxYear Independent of tariff For tariff 1 only For tariff 2 only For tariff 1 + tariff 2 For current day and each of the last 10 da.


2SD1554 U1602 U1603


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)