Dual Retriggerable Resettable Monostable Multivibrator
DM96LS02 Dual Retriggerable Resettable Monostable Multivibrator
October 1988 Revised March 2000
DM96LS02 Dual Retrigge...
Description
DM96LS02 Dual Retriggerable Resettable Monostable Multivibrator
October 1988 Revised March 2000
DM96LS02 Dual Retriggerable Resettable Monostable Multivibrator
General Description
www.DataSheet4U.com
The DM96LS02 is a dual retriggerable and resettable monostable multivibrator. The one-shot provides exceptionally wide delay range, pulse width stability, predictable accuracy and immunity to noise. The pulse width is set by an external resistor and capacitor. Resistor values up to 1.0 MΩ reduce required capacitor values. Hysteresis is provided on both trigger inputs of the DM96LS02 for increased noise immunity.
Features
s Required timing capacitance reduced by factors of 10 to 100 over conventional designs s Broad timing resistor range—1.0 kΩ to 2.0 MΩ s Output Pulse Width is variable over a 2000:1 range by resistor control s Propagation delay of 35 ns s 0.3V hysteresis on trigger inputs s Output pulse width independent of duty cycle s 35 ns to ∞ output pulse width range
Ordering Code:
Order Number DM96LS02M DM96LS02N Package Number M16A N16E Package Description 16-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150 Narrow 16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide
Devices also available in Tape and Reel. Specify by appending the suffix letter “X” to the ordering code.
Logic Symbol
Connection Diagram
VCC = Pin 16 GND = Pin 8
Pin Descriptions
Pin Names I0 I0 I1 CD Q Q Description Trigger Input (Active Falling Edge) Schmitt Trigger...