Document
LHR, LGR 4/5000 Series
10...30 Watt AC-DC Converters
Input voltage ranges 85...265 V AC 88…168 V DC 1 or 2 outputs up to 48 V DC 4300 V DC I/O electric strength test voltage
LGA
• Class II equipment (double insulation) • Short circuit protection • Compact, low cost solution
Selection chart
Output 1 Uo nom Io nom [V DC] [A] 3.3 3 3.3 7 5 2 5 5 12 1.2 12 2.5 15 1 15 2 24 0.6 24 1.25 3.3 1.5 3.3 2.5 +5 1.25 +5 2.5 +5 1 +5 2.5 +12 0.6 +12 1.25 +15 0.5 +15 1.0 +24 0.3 +24 0.625 Output 2 Uo nom Io nom [V DC] [A] +5 1 +5 2.5 -5 1.25 -5 2.5 +12 0.5 +12 1.25 -12 0.6 -12 1.25 -15 0.5 -15 1.0 -24 0.3 -24 0.625 Input voltage Ui Rated power TA = 50 °C Po tot [W] 10 23 10 25 14.4 30 15 30 14.4 30 10 20.8 12.5 25 11 27.5 14.4 30 15 30 15 30 Type
85…264 V AC (47…63 Hz) 88…168 V DC
LHR 4101-2 LGR 4101-2 LHR 4001-2 LGR 4001-2 LHR 4301-2 LGR 4301-2 LHR 4501-2 LGR 4501-2 LHR 4601-2 LGR 4601-2 LHR 5101-2 LGR 5101-2 LHR 5001-2 LGR 5001-2 LHR 5020-2 LGR 5020-2 LHR 5320-2 LGR 5320-2 LHR 5540-2 LGR 5540-2 LHR 5660-2 LGR 5660-2
www.power-one.com
Edition 5/07.2001
1
Board Mountable
Input
Input voltage Input frequency continuous range
LHR, LGR 4/5000 Series
85...264 V AC / 88…168 V DC 47...63 Hz
Output
Efficiency Output voltage switching noise Line and load regulation Uo1 Line and load regulation Uo2 Minimum load Hold-up time 230 V AC, Io nom Ui nom, Io nom, 20 MHz bandwidth, peak-peak Ui min…Ui max, (10…100%) • Io nom Ui min…Ui max, (10…100%) • Io nom not required on single output types recommended 0.1 Io nom on double output types 110/230 V AC, Io nom up to 86% <1% ±1% ±2%
>10 ms
Protection
Output overload Short circuit No load hiccup mode on LHR types / rectangular on LGR types
Control
Trim /R ±80…110% Uo nom
Safety and EMC
Safety marks Electric strength test voltage Electrostatic discharge Electromagnetic field Electr. fast transients/burst Surge Electromagnetic emissions 900 MHz Test UL, ULc, CE I/O IEC/EN 61000-4-2, level 4 (15 kV) IEC/EN 61000-4-3, level 3 (10 V/m) IEC/EN 61000-4-4, level 3 (i, ±2 kV) IEC/EN 61000-4-5, level 3 (2 kV) CISPR 22/EN 55022, conducted ENV50204, 3V/m 3000 V AC criterion A criterion A criterion A criterion A class B criterion A
Environmental
Ambient temperature Storage temperature Relative humidity Shock Random vibration
Ui nom, Io nom, convection cooled non operational non condensing peak acceleration
–10...50 °C –40...100 °C 5...95% 20 gn 2 gn rms
Options
Trim pin not fitted (single output units only)
www.power-one.com
Edition 5/07.2001
2
LHR, LGR 4/5000 Series
Mechanical data
10...30 Watt AC-DC Converters
European Projection
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
40.6 (1.59") 7.6 (0.3")
S09005
LHR
10.1 (0.4")
5 ø 0.8x0.8 4
6
3
66 (2.60")
76.2 (3")
41.7 (1.64")
1 23 (0.91")
+0.5/-0
2 25.4 (1") 50.8 (2")
4.5 (0.18")
Measuring point of case temperature TC
LGR
S09006
ø 0.8 x 0.8
7
6
5
4
3
88.9 (3.5")
54.4 (2.14")
81.2 (3.2")
1 4.5 (0.18") 25.4 (1") 55.9 (2.28") 63.5 (2.5") Measuring.