TO-39 / TO-5 housing Competitive cost version Designed for motion control
The LHi 874 and LHi 878 pyroelectric infrared-detector series are the standard dual element design recommended for all variants of motion control.They include a dual element pyro-electric ceramic with FET in source follower connection. The LHi 874 is available as TO-39, whereas LHi 878 detector is available in TO-5 housing with standard infrared filter. They both offer high responsivity with excellent common mode performance (match) and low noise at steady state and temperature changes. For both variants RF improved options are available.
Parameters
p
D A T A S H E E T
LHi 874/ 878
min typical ma x units condition
Element size R esponsivity Match Noise Offset Voltage
2x1 3 300 4000 1 20 0,2 10 50 1,55
mm2 V /W % µV pp V
(2 elements) 100°C, 1 Hz
25°C , 0,3...10Hz RS =47kW , 25°C
Right for modification reserved / WS /, 29.6.2001
NEP D* Output Impedance Operating Voltage Field of View, vertical horizontal
Field of View
7,5x10-10 28x10-10 5x10
7
W Ö Hz
1Hz Bw, 100°C, 1 Hz
19x10 5
7
cm Ö Hz/W 1Hz Bw,100°C, 1 Hz 10 15 kW V ° ° 85 85 °C °C RS =47kW , 25°C RS =47kW , 25°C unobstructed unobstructed non permanent non permanent
2 95 90
Operating Temperature -40 S torage Temperature
-40
100
LHi 874
LHi 878
10 R [kV/W] 1 0,1 0,01
0,1 f [H z]
1
10
Frequency Response