DatasheetsPDF.com

FN2010 Dataheets PDF



Part Number FN2010
Manufacturers Schaffner
Logo Schaffner
Description General Purpose AC/DC EMI Filter
Datasheet FN2010 DatasheetFN2010 Datasheet (PDF)

DATASHEET Single-Stage Filters FN 2010 General Purpose AC/DC EMI Filter Rated currents from 1 to 60 A General purpose filtering performance Optional medical versions (B type) Optional safety versions (A type) Optional enhanced performance versions Optional DC optimized versions Approvals Performance indicators Technical specifications Rated voltage* Operating frequency Rated currents High potential test voltage Temperature range (operation and storage) Certified to Flammability correspondi.

  FN2010   FN2010


Document
DATASHEET Single-Stage Filters FN 2010 General Purpose AC/DC EMI Filter Rated currents from 1 to 60 A General purpose filtering performance Optional medical versions (B type) Optional safety versions (A type) Optional enhanced performance versions Optional DC optimized versions Approvals Performance indicators Technical specifications Rated voltage* Operating frequency Rated currents High potential test voltage Temperature range (operation and storage) Certified to Flammability corresponding to MTBF @ 40°C/230 V (Mil-HB-217F) 250 VAC, 50/60 Hz; 250 VDC DC to 400 Hz 1 to 60 A @ 40°C max. P –> PE 2000 VAC for 2 sec (equiv. cap <88 nF) P –> PE 2550 VDC for 2 sec (equiv. cap >88 nF) P –> PE 2500 VAC for 2 sec (B types) P –> N 1100 VDC for 2 sec -25 °C to +100 °C (25/100/21) UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to AC and DC applications) UL 94 V-2 or better 1,250,000 hours 3,200,000 hours (B types) *maximum RMS operating voltage at rated frequency or the maximum DC operating voltage Features and benefits FN 2010 filters are designed for easy and fast chassis mounting FN 2010 filters are available as B versions without Ycapacitors for medical applications as well as A version with low capacitance for safety critical applications with necessity for low leakage currents FN 2010 filters are also available as enhanced performance and DC optimized versions. With higher attenuation in very compact housing (M, N1,N types) All filters provide a general purpose conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior FN 2010 filters can be used to cover a broad range of usage and they offer a good size/amperage ratio Various terminal options allow you to select the desired connection style Typical applications Electrical and electronic equipment Consumer goods Household equipment Medical equipment Office automation equipment Datacom equipment Typical electrical schematic 2 EMC/EMI Products Schaffner Group Datasheets 14 Mar 2019 Filter selection table Filter* Rated current @ 40°C (25°C) Leakage current** @ 250 VAC/50 Hz (@ 120 VAC/60 Hz) Inductance L Capacitance Cx Cy Resistance R Input/Output connections Weight FN 2010-1-.. FN 2010-3-.. FN 2010-6-.. FN 2010-10-.. FN 2010-12-.. FN 2010-16-.. FN 2010-20-.. FN 2010-30-08 FN 2010-60-24 [A] 1 (1.15) 3 (3.45) 6 (6.9) 10 (11.5) 12 (13.8) 16 (18.4) 20 (23) 30 (34.5) 60 (69) [mA] 0.66 (0.38) 0.66 (0.38) 0.66 (0.38) 0.66 (0.38) 0.66 (0.38) 0.66 (0.38) 0.66 (0.38) 0.79 (0.46) 0.79 (0.46) [mH] [μF] [nF] 12 0.1 4.7 2.5 0.1 4.7 1 0.1 4.7 0.8 0.1 4.7 0.7 0.1 4.7 0.7 0.1 4.7 0.6 0.1 4.7 0.7 0.47 10 1 1.5 10 [kΩ] 1000 1000 1000 1000 1000 1000 1000 1000 330 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -08 -08 -24 [g] 65 65 65 85 85 140 210 470 1100 FN 2010 A-1-.. FN 2010 A-3-.. FN 2010 A-6-.. FN 2010 A-10-.. FN 2010 A-12-.. FN 2010 A-16-.. FN 2010 A-20-.. FN 2010 A-30-08 FN 2010 A-60-24 1 (1.15) 3 (3.45) 6 (6.9) 10 (11.5) 12 (13.8) 16 (18.4) 20 (23) 30 (34.5) 60 (69) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 12 0.1 0.47 2.5 0.1 0.47 1 0.1 0.47 0.8 0.1 0.47 0.7 0.1 0.47 0.7 0.1 0.47 0.6 0.1 0.47 0.7 0.47 0.47 1 1.5 0.47 1000 1000 1000 1000 1000 1000 1000 1000 330 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -08 -08 -24 65 65 65 85 85 140 210 470 1100 FN 2010 B-1-.. FN 2010 B-3-.. FN 2010 B-6-.. FN 2010 B-10-.. FN 2010 B-12-.. FN 2010 B-16-.. FN 2010 B-20-.. FN 2010 B-30-08 FN 2010 B-60-24 1 (1.15) 3 (3.45) 6 (6.9) 10 (11.5) 12 (13.8) 16 (18.4) 20 (23) 30 (34.5) 60 (69) 0.00 12 0.1 0.00 2.5 0.1 0.00 1 0.1 0.00 0.8 0.1 0.00 0.7 0.1 0.00 0.7 0.1 0.00 0.6 0.1 0.00 0.7 0.47 0.00 1 1.5 1000 1000 1000 1000 1000 1000 1000 1000 330 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -06 -07 -08 -08 -24 65 65 65 85 85 140 210 470 1100 Enhanced performance FN 2010 N1-1-06 FN 2010 N1-3-06 FN 2010 N1-6-06 FN 2010 N1-10-06 FN 2010 N1-12-06 FN 2010 M-16-06 FN 2010 M-20-.. FN 2010 N-30-08 FN 2010 N-60-24 1 (1.15) 3 (3.45) 6 (6.9) 10 (11.5) 12 (13.8) 16 (18.4) 20 (23) 30 (34.5) 60 (69) 5.34 (3.08) 5.34 (3.08) 5.34 (3.08) 5.34 (3.08) 3.69 (2.13) 3.69 (2.13) 3.69 (2.13) 7.85 (4.52) 7.85 (4.52) 12 0.1 2.5 0.1 1 0.1 0.8 0.1 0.7 0.1 0.7 0.1 0.6 0.1 0.7 0.47 1 1.5 68 68 68 68 47 47 47 100 100 1000 1000 1000 1000 1000 1000 1000 1000 330 -06 -06 -06 -06 -06 -06 -06 70 70 70 85 85 140 -08 220 -08 400 -24 1120 ** To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2010-30-08, FN 2010B-10-06). The different letters code the used Cy values in the filter type (A = 0.47nF; M = 47nF; N1 = 47nF; N = 100nF) ** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. 3 EMC/EMI Products Typical filter attenuation Per CISPR 17; A=50 Ω/50.


VN0606N FN2010 EM640FP16


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)