Features
• Category 3 or 4 • Contacts (5 µm gold pla...
Description
Emergency Stop www.DataSheet4U.com
Type BO 5988 safemaster
Relay
Features
Category 3 or 4 Contacts (5 µm gold plated) .61 - 6 N/O, 1 N/C .47 - 3 N/O, 1 N/C, 1 N/O delayed release Removable terminal strips for fast replacement Internal auxiliary power supply protection with auto-reset Dual voltage AC and 24V DC power supply Link programmable Single or dual channel operation Auto or manual reset Short circuit/link monitoring of Estop and reset pushbutton circuits
Models BO 5988.61, BO 5988.47
CANADA
USA
Technical Committee of Electrical Engineering
Typical Schematic Diagram
Description
BO 5988.61 Category 3 applications
Fit links S21 - S23 X1 - X2
L
Emergency Stop RelayT ype BO 5988 complies fully with the requirements of the standard specifications referred to on page 3 of this publication. It is a derivative of models BN 5983 / BD 5987 utilising fail-safe control logic to offer greatly extended control capability within a compact 100 mm wide DIN rail mounted enclosure.
OFF
EMERG. STOP
A4 S11 A1 A3(+) S12 S21 S23 S22 S12 13 23 33 43 53 63 81 (–)
Circuit Connections
LOGIC
K2 K3
ON RESET
Y1 Y2
PE (–)
X1
X2 X5 X6
14 24 34 44 54 64 82 A2
N
Diag 1
BO 5988.61 with External contactors. This diagram shows how external contactors with positive guided contacts C1 and C2 can be used to reinforce the switching capacity of BO 5988.61 with continued redundancy
L
The adjacent circuit (diag. 1) is for standard 2 channel input, manual reset operation. The...