Sakety Relay
www.DataSheet4U.com
50 Series - Safety relay 8 A
50.12
Features
PCB Relay with forcibly guided contacts according to E...
Description
www.DataSheet4U.com
50 Series - Safety relay 8 A
50.12
Features
PCB Relay with forcibly guided contacts according to EN 50205 type B 2 CO contacts * High physical separation between adjacent contacts Cadmium Free contact materials 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts Flux proof: RT II
2 Pole 8 A 5 mm pinning PCB mounting
29
12.4
A1 12 11 14
25
A2
22 21 24
5
0.4
1
5 5
=
1.5
2.5
20 29
6
*According to EN 50205 only 1 NO and 1 NC (11-14 and 21-22 or 11-12 and 21-24) shall be used as forcibly guided contacts.
FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE “General technical information” page V
Contact specification Contact configuration Rated current/Maximum peak current Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load Standard contact material Coil specification Nominal voltage (UN) Rated power AC/DC Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC Electrical life at rated load AC1 Operate/release time Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) cycles cycles ms V AC °C V AC (50/60 Hz) VA (50 Hz)/W AC (50 Hz) DC AC/DC AC/DC A VA VA kW A Rated voltage/Maximum switching voltage V AC
Copper side view
2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.2 300 (5/5) AgNi — —/0.7 — (0.75…1.2)UN —/0.4 UN —/0.1 UN —/10 · 106 100 · 103 10/4 6 (...
Similar Datasheet