Document
Catalog 1308961
www.DataSheet4U.com
Issued 6-01
PCD/PCDF series
15 Amp Low Profile Power PC Board Relay
Appliances, HVAC, Office Machines UL File No. E82292 CSA File No. LR48471 TUV File No. R9751117
Features
• Low profile (10mm), 15 Amp switching capacity. • 1 Form A contact arrangement. • Sensitive 200mW coil (250mW on 48VDC coil). • Immersion cleanable, sealed version available. • Quick connect terminals available (PCDF).
Coil Data @ 20°C
PCD &PCDF Rated Coil Voltage (VDC) 3 5 6 9 12 24 48 Nominal Current (mA) 67.0 40.0 33.3 22.5 17.0 8.6 5.2 Coil Resistance (ohms) ± 10% 45 125 180 400 720 2,880 9,200 Must Operate Voltage (VDC) 2.25 3.75 4.50 6.75 9.00 18.00 36.00 Must Release Voltage (VDC) 0.30 0.50 0.60 0.90 1.20 2.40 4.80
Contact Data @ 20°C
Arrangements: 1 Form A (SPST-NO). Material: AgSnO. Max. Switching Rate: 300 ops./min. (no load). 30 ops./min. (rated load). Expected Mechanical Life: 10 million operations (no load). Expected Electrical Life: 100,000 operations (rated load). Minimum Load: 100mA @ 5VDC. Initial Contact Resistance: 100 milliohms @ 1A, 6VDC.
Operate Data Contact Ratings
Ratings: 15A @ 125VAC resistive (PCDF only, load must be carried through QC terminals to achieve this rating), 10A @ 250VAC resistive, 10A @ 24VDC resistive. 5A @ 125VAC inductive (cosø= 0.4, L/R=7msec), 5A @ 24VDC inductive (cosø= 0.4, L/R=7msec). Max. Switched Voltage: AC: 250V. DC: 24V. Max. Switched Current: 15A. Max. Switched Power: 1,800VA, 240W. Must Operate Voltage: 75% of nominal voltage or less. Must Release Voltage: 10% of nominal voltage or more. Operate Time: 15 ms max. Release Time: 8 ms max.
Environmental Data
Temperature Range: Operating: -30°C to +70°C Vibration, Mechanical: 10 to 55 Hz., 1.5mm double amplitude Operational: 10 to 55 Hz., 1.5mm double amplitude. Shock, Mechanical: 1,000m/s2 (100G approximately). Operational: 100m/s2 (10G approximately). Operating Humidity: 20 to 85% RH. (Non-condensing).
Initial Dielectric Strength
Between Open Contacts: 750VAC 50/60 Hz. (1 minute). Between Coil and Contacts: 2,500VAC 50/60 Hz. (1 minute). Surge Voltage Between Coil and Contacts: 5,000V (1.2 / 50µs).
Initial Insulation Resistance
Between Mutually Insulated Elements: 1,000M ohms min. @ 500VDCM.
Mechanical Data Coil Data
Voltage: 3 to 48VDC. Nominal Power: 200 mW except 48VDC coil (250mW). Coil Temperature Rise: 20°C max., at rated coil voltage. Max. Coil Power: 130% of nominal. Duty Cycle: Continuous. Termination: PCD: Printed circuit terminals. PCDF: Printed circuit terminals and quick connect terminals. Enclosure (94V-0 Flammability Ratings): Sealed plastic case. Weight: PCD: 0.31 oz (9g) approximately. PCDF: 0.35 oz (10g) approximately.
30
Tyco Electronics Harrisburg, PA U.S.A. Dimensions (for reference purposes only) are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. Technical Support: 1-800-522-6752 http://relays.tycoelectronics.com
www.DataSheet4U.com Ordering Inform.