Chokes
www.DataSheet4U.com
Chokes for Power Lines Sine-Wave Chokes
Rated voltage 250 Vac Rated current 0,8 to 2,7 A Rated induc...
Description
www.DataSheet4U.com
Chokes for Power Lines Sine-Wave Chokes
Rated voltage 250 Vac Rated current 0,8 to 2,7 A Rated inductance 0,5 to 3,0 mH Construction
s s s s
B82614
Choke consisting of rectangular ferrite core with air gap Closed polycarbonate coil former with 4 sections Without encapsulation One winding
Features
s Coil former flame-retardant as per UL 94 V-0 s Recycleable owing to omission of encapsulation and glue
Applications
s Switch-mode power supplies with current pump s Reduced harmonics input current
Terminals
s Pins 0,7 × 0,7 mm s Lead spacing 15 × 12,5 mm
Marking Manufacturer, ordering code, rated current, rated inductance, rated current Dimensional drawing and pin configuration
15±0,2 21 max. 8,1 max.
32,5 max.
23,3 max.
12,5±0,2
0,7
3+0,5
SSB1389-V
31 max.
330 04/00
Chokes for Power Lines Sine-Wave Chokes
General technical data Rated inductance LR Measured with HP 4275 A or HP 4284 A; Measuring frequency: L ≤ 1 mH = 100 kHz L > 1 mH = 10 kHz ± 30 % Typical values, measured at 20 °C 250 Vac / 350 Vdc
B82614
Inductance tolerance DC resistance Rtyp Rated voltage VR Climatic category Standards Weight Current derating Iop/IR versus ambient temperature TA
In accordance with IEC 60068-1 40/125/56 (– 40 °C/+ 125 °C/56 days damp heat test) The chokes comply with EN 60938-2 und VDE 0565-2 Approx. 30 g
1,4
IΙop B IΙR R 1,2
SSB1102-8
1,0 0,8 0,6 0,4 0,2 0
0
20
40
60
80
100
C 140 TA
Characteristics and ordering codes
IR A
0,8 1,0 1,7 2,0 2,4 2,7...