DC spark-over voltage 1) 2) Impulse spark-...
Description
Surge Arrester 2-Electrode-Arrester
A80-C90X Ordering code: B88069X1410C103
DC spark-over voltage 1) 2) Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution at 1 kV/µs - for 99 % of measured values - typical values of distribution
90 ± 20 < 500 < 450 < 600 < 550 20 25 5 20 100 > 10 < 1.5 ~ 10 ~ 0.5 ~ 60 ~ 1.5 -40 ... +90 40/ 90/ 21 90 YY O
90 YY O - Nominal voltage - Year of production - Non radioactive
V % V V V V kA kA kA A A GΩ pF V A V g °C
Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 10/350 µs) Nominal alternating discharge current (50 Hz, 1 s) Alternating discharge current (50 Hz, 9 cycles) Insulation resistance at 50 Vdc Capacitance at 1 MHz Arc voltage at 1 A Glow to arc transition current Glow voltage Weight Operation and storage temperature Climatic category (IEC 60068-1) Marking, blue
1) 2)
At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM Page 1 of 2
Issue 03, 18.04.2002
Surge Arrester 2-Electrode-Arrester
A80-C90X Ordering code: B88069X1410C103
Not to scale Dimensions in mm Non controlled document