Document
www.DataSheet4U.com
COMPACT POWER RELAY 1 POLE—20 A (For Automotive Applications)
FBR53 SERIES
n FEATURES
l l
Compact for high density packaging High contact capability (40A continuous) l High temperature grade (-40˚C to 125˚C) l Contact arrangement Form U (form A)
n ORDERING INFORMATION
[Example]
FBR53 ND 012 - Y - *** (a) (b) (c) (d) (e)
(a) (b) (c) (d) (e)
Series Name Nominal Voltage Contact Material Custom designation
FBR-53 : FBR-53 Series : Form U : 9 VDC : 10 VDC : 12 VDC : Silver Tin Oxide Alloy : Standard : High capacity 09 10 12 Y Nil -HW
Contact Arrangement ND
Note: The part number on the relay cover does not include 'FBR' Example: Ordering part number: FBR-53ND12-Y Stamped part number: 53ND12-Y
FBR53 SERIES
n COIL DATA CHART
Standard Model FBR53ND09-Y FBR53ND10-Y FBR53ND12-Y Nominal Voltage 9 VD C 10 VD C 12VD C Coil Resistance (±10% at 20˚C) 13 5 Ω 18 0 Ω 24 0 Ω Must Operate Voltage 5.4 VDC (at 20˚C) 6.8 VDC (at 85˚C) 6.3 VDC (at 20˚C) 7.9 VDC (at 85˚C) 7.3 VDC (at 20˚C) 9.2 VDC (at 85˚C)
High capacity Model FBR53ND09-Y-HW FBR53ND10-Y-HW FBR53ND12-Y-HW Nominal Voltage 9 VD C 10 VD C 12VD C Coil Resistance (±10% at 20˚ C) 94 Ω 11 7 Ω 16 7Ω Must Operate Voltage 5.4 VDC (at 20˚C) 7.7 VDC (at 125˚C) 6.3 VDC (at 20˚C) 9.0 VDC (at 125˚C) 7.3 VDC (at 20˚C) 10.4 VDC (at 125˚C)
FBR53 SERIES
n SPECIFICATIONS
It em Arrangement Material Contact rating Contact Maximum Carrying Current Maximum Inrush Current Contact Resistance Coil Power Consumption (at rated coil voltage) Coil Operating Temperature Range Storage Temperature Range Operating Humidity Initial resistance Insulation Dielectric withstanding voltage between coil and contacts Time Life Operate (at nominal voltage) Release (at nominal voltage) Mechanical Electrical Misoperation Vibration resistance Endurance Misoperation Other Shock resistance Endurance Solderability Terminal Weight Strength Sp ec i f i c at i o n Standard Form U (Form A) Silver Tin Oxide DC 14V, 20A (resistive load) 20A continuous (10A each contact) at 25˚ C 60A inrush (30A each contact) at 25˚ C Approximately 0.6 W -40° C to +125° C (no frost) -40° C to +125° C (no frost) 45 to 85%RH 100MΩ maximum at 500VDC, (at 20˚ C, 65%RH) 500 VAC 50/60 Hz 1 minute, (at 20˚ C, 65%RH) 10 ms maximum 5 ms maximum 10x106 operations minimum (with no load for contact) 1x105 operations minimum (14VDC 20A resistive load) 10-55Hz,1.5mm dual amplitude, direction X, Y, Z 10 to 100Hz, 1.5mm dual amplitude, direction X, Y, Z. Not be damaged (mechanical and technical) after test. Coil energizing: 1 hr in each direction, Coil nonenergizing: 1 hr in each direction 100 m/s2 (11ms), direction X, Y, Z 1000 m/s2 (11ms), direction X, Y, Z, each 6 times Not be damaged (mechanical and technical) after test. Coil energizing: 3 times; Coil non-energizing: 3 times, total 36 times. at 270±10˚ C for 3±0.5sec. (terminals must be soldered) Pulling a terminal in .