AC/DC converter
www.DataSheet4U.com
AC/DC converter
AC100V input, 12V/30mA output
BP5038A
Absolute Maximum Ratings
Parameter Input vo...
Description
www.DataSheet4U.com
AC/DC converter
AC100V input, 12V/30mA output
BP5038A
Absolute Maximum Ratings
Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range Symbol Vi Io Vsurge Topr Tstg Limits 170 30 2 −20 to +80 −20 to +85 Unit V mApk kV °C °C
Dimensions (Unit : mm)
18.0MAX. 9.1MAX. Mark Side 1 4 5 6 P = 2 . 5 4 ±0 . 2 0 . 2 5 ±0 . 0 5 3.0MAX. 6.1MAX. 1.3 ±0.2 3.3MAX 0 . 5 ±0 . 1 2.54×5=12.7
Electrical Characteristics
Symbol Min. Parameter Input voltage range 113 Vi Output voltage 11.0 Vo Output current 0 Io Line regulation − Vr Load regulation − Vl Output ripple voltage − Vp Power conversion efficiency 40 η Typ. 141 12 − 0.17 0.19 0.05 50 Max. 170 13.0 30 0.3 0.3 0.15 − Unit V V mA V V Vp-p % Conditions DC(80 to 120VAC) Vi=141V, Io=30mA Vi=141V Vi=113 to 170V, Io=30mA Vi=141V, Io=0 to 30mA Vi=141V, Io=30mA Vi=141V, Io=30mA
Derating Curve
Derating Curve 40 35 30 25 20 Operation Range 15 10 5 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta(°C) Output Current Io(mA)
∗1 ∗2 ∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Please refer to Load regulation, Conversion efficiency.
Switching Frequency
Switching Frequency fsw(kHz) 140 120 100 80 60 40 20 0 0 5 10 15 20 25 Output Current Io(mA) 30 Switching Frequency (Ta=25°C, Vi=141V)
Application circuit
BP5038A
Pin No. 1 2 3 4 5 6 Function Input terminal Vi(141VDC) Skip Skip COMMON COMMON Output termi...